The paper describes the electro-capacitive method for monitoring wire capacitance, which is implemented using the CAP-10 device, employed for in-process testing of the single core electric wire capacitance. Focus is made on the operating principle of the CAP-10 device. The possibility of using the CAP-10 device for detecting local defects in wire insulation is proved. Insulation defects such as foreign inclusions in the form of copper shavings, air cavities inside insulation and those at the core–insulation boundary are modeled. The impact of the defect geometric parameters on the wire capacitance measured during in-process testing is investigated through numerical simulation. Mathematical simulation results are validated through the physical model using the CAP-10 device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.