The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference dosimeter. Some general characteristics of Fricke dosimeter such as energy dependence, optical density (OD)-dose relationship, reproducibility, accuracy, dose rate dependence were analyzed. The Fricke solution shows linearity in OD-dose relationship, energy independence and a good reproducibility over the energy range investigated. The Fricke dosimeter was found to be suitable for carrying out absorbed dose to water measurements in the calibration of high energy electron and photon beams.
The main objective of this study was to investigate the Fricke dosimeter water equivalent system for measurement of dosimetric parameters for photon beam. The parameters measured with the Fricke dosimeter were compared to those obtained with an ionization chamber. In this work characteristics for 60 Co γ-rays of field sizes ranging from 5 × 5 cm 2 to 20 × 20 cm 2 are reported. The measurements were carried out in the secondary standard dosimetry laboratory using a collimated 60 Co gamma source therapy unit. The 60 Co beam output in terms of absorbed dose to water was obtained as per IAEA TRS 398 recommendations using cylindrical ionization chamber, whose N D,w has been supplied by the IAEA's reference laboratory. Specific quantities measured include: output factors, peak scatter factor, lateral beam profiles and percentage depth dose. The Fricke dosimeters were irradiated in a water phantom using the suitable poly (methyl methacrylate), PMMA stand. Our results demonstrate that Fricke dosimeter and ionization chamber agree with each other.
The effective atomic number and electron density of some Fricke gel dosimeters were calculated for photon interaction in the energy range from 10 keV to 1000 MeV using Auto-Zeff, direct and power law methods. The results are presented relative to those of water to allow direct comparison. It is found, that the effective atomic numbers and effective electron densities calculated with the Auto-Zeff and direct methods, demonstrates a good agreement in the energy interval extending from 0.1 MeV to 10 MeV. For effective atomic number relative to water, Ferrous Agarose Xylenol gel showed better water equivalence with difference up to 0.3%, while FX-PVA-GTA and Ferrous Xylenol Gelatin gels showed differences up to 2.26% and 2.25%, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.