Organic anions accumulated in blood serum of patients with chronic renal failure were separated by a novel technique: closed-system capillary zone electrophoresis (CZE) in a pH6 carrier-electrolyte system. Hippuric acid (HA), p-hydroxyhippuric acid, and uric acid were identified by their co-elution with standards prepared in ultrafiltered normal serum and by comparison with the corresponding ultraviolet-detected peaks positively identified in the HPLC analyses. Analysis time for the entire profile is 8 min. Repeatabilities (CVs) of CZE migration times and peak areas of the three acids in serum samples were about 0.7% and 6%, respectively. We quantified HA in 10 ultrafiltered uremic serum samples and compared results with those by a previously described HPLC procedure. The very good agreement further supports the identification of hippuric acid. Accuracy and precision of the CZE method were similar to those for the HPLC gradient-elution method, but analysis time for HA (8 min) is much less than by HPLC (90 min). Our technique is very suitable for selective, rapid analysis for (ultraviolet-absorbing) anionic constituents in ultrafiltered uremic serum, without any sample pretreatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.