An international comparison of He-Ne/I 2 lasers at λ 633 nm between the CMI (Czech Republic), the OMH (Hungary) and the BEV (Austria) was performed at the CMI-LPM, Prague, in July 1997 as DUNAMET project D3. The frequencies of three national standards of length (lasers) were found to be in the range ± 7 kHz (1.5 parts in 10 11 ) and reproducibility of frequency differences between individual lasers during one week was better than ± 5 kHz (1 part in 10 11 ). The relative frequency stability, expressed as an Allan standard deviation, reached a minimum of 3 parts in 10 13 for an integration time of 10 000 s.
Background Therapeutic drug monitoring (TDM) is the clinical practice of measuring serum drug concentrations to guide clinical decision-making. In IBD patients, it is applied mainly in infliximab (IFX) and adalimumab (ADL) therapy. TDM is either performed reactively in response to disease activity, or proactively in the absence of symptoms. The aim of the present study was to compare two analytical methods for the detection of trough infliximab and adalimumab levels (TL): point-of-care (POCT) fluorescence resonance energy transfer (FRET) method, and the enzyme- linked immunosorbent immunoassay (ELISA). Methods TL IFX were measured in n=24 and TL ADL in n= 21 blood samples. For ELISA, standard peripheral venous samples were used, and for POCT FRET measurements, capillary finger puncture was performed. Two assay results were compared evaluating the regression relationship using Spearman’s correlation coefficient and the Bland-Altman plots. Cohen’s kappa analysis was used to compare the degree of qualitative agreement between the two data sets. Repeatability was assessed by the difference of the repeated measurements, their means and standard deviations. Results The high degree of correlation was found between the measured values, both qualitative and quantitative (p < 0.0001 for both IFX and ADL), either expressed by the Spearman’s correlations, or by Bland-Altman analysis. Cohen’s weighted kappa 0.903 for IFX and 0.834 for ADL showed substantial/almost perfect agreement of qualitative results. Closeness of the agreement of successive measurements was very acceptable for both TLs of both drugs. Conclusion Point-of-care detection of IFX and ADL trough levels by FRET is accurate, comparable to the reference method, analysis is sufficiently consistent. For clinical sites with a proactive approach to TDM, FRET may be a useful tool for decision-making regarding individualization of biologic therapy. Acknowledgements: We thank ProciseDX company for the ProciseDX analyzer rental, and for providing the laboratory diagnostics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.