Polarization methods are widely used in studies of different physical, chemical and geometrical characteristics of objects. The spectrum of such methods application is wide enough. The results, received using these methods allow to measure the phase characteristics of wavelength with the accuracy of iO X.The basic tendency of these methods development and modernization is aimed at the miniaturization of the polarization measuring means. The optical polarization sensors that are developed and produced at the Technological Institute of Applied Microelectronics (SB RAS) have the original circuit solutions, which allow decreasing the mass-dimensional and electrical characteristics of articles. The results of optical polarization sensors application in studies of biological and chemical processes and gas sorption kinetics as well as in investigations of rock mechanical properties are presented in this paper.
The used methodology of the scientific substantiation of indicators is in the establishment of the conformity of laws of vital activity of indicator and pathogenic microorganisms in the real conditions of the action of the complex of factors, including disinfecting agents. In the one water sample simultaneously there were determined both the general indicator (GICB), thermotolerant (TTCB), glucose positive (GPCB) coliform bacteria, E.coli. On the base of long-term research in the various regions of the Russian Federation, as well with bearing in mind the analysis of domestic and foreign data, comparing the water quality and the incidence of intestinal infections in population it is recommended to use the index of determination of the total number glucose positive coliform bacteria (GPCB), which brings together a much broader range of bacteria of the Enterobacteriaceae family in comparison with total coliform bacteria (TCB) and thermotolerant coliform bacteria (TTCB) and warrants the absence in the test volume of water as an indicator lactose positive (E.coli, TCB, TTCB) and pathogens (salmonella) and potentially pathogenic bacteria which do not ferment lactose. Proposed index of GPCB is shown to allow to assess epidemiological risks not only more accurate, but also more efficiently without increasing the cost performance of bacteriological research.
Introduction. The main task of treating sewage sludge is to obtain the final product, the properties of which would ensure the possibility of its utilization and minimize the damage to the environment. The sanitary and hygiene characteristics of the sediment are assessed by the presence of pathogenic microorganisms and helminths eggs. The degree of disinfection of the sediments is controlled according to SanPiN 2.1.7.573 - 96. The objective of the work. Determination of optimal doses of caustic lime for disinfection of microbial contamination of sewage sludge of household wastewater of sewerage cleaning facilities (SCF) and liquid manure of the swine complex. Material and methods. The object of the study were microbial communities of the sludge of the SCF household wastewater and liquid manure of the swine complex. Standard microbiological research methods were used in the work according to MU 2.1.5.800 - 99 and MR N FTs/4022. For representativeness, analyses were performed in triplicate. Results. Caustic lime was added in the amount of 1 to 10% of the volume (mass) of the sludge under study into the sludge of household wastewater (humidity of 97 - 98%). The contact time was 0.5 hours, 1 hour, 3 hours. At a concentration of caustic lime of 5 and 6%, the absence of microflora was noted after 1 hour, at a concentration of caustic lime 8 - 10% - after 0.5 hours. After 3 hours, for any amount of caustic lime (from 1 to 10%) in the native sludge of wastewater sewerage, all the microorganisms under study were not shown. Into the liquid manure (humidity less than 85%), caustic lime was added in the amount of 4 - 10% of the volume (mass) of the material being examined. The exposure was of 1 and 3 hours. The complete death of microbes at any exposure was observed at a concentration of caustic lime 9 and 10%. Conclusion. The investigations have shown the dynamics of death of microorganisms in studying the impact of caustic lime on both native and sterilized material to be the same. The total death of microorganisms during the treatment of sludge from household wastewater was observed at a concentration of caustic lime of 7 - 9%. The complete death of microbes in liquid manure (native and sterilized) at any exposure was observed at a concentration of caustic lime 9 and 10%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.