The use of the CO2 laser seems associated with the best functional results, although on a statistical basis, they do not differ significantly from that obtained with the standard MD platinotomy. The PZS stapedotomy is effective from a surgical point of view for most patients. However, it is associated with a slight but significant deterioration of BC at high frequency and at higher vertigo rate. More basic validation of the stimulation parameters is necessary for safe use of this new technology.
Introduction Bone anchored hearing solutions are a well-known option for patients with a conductive, mixed conductive-sensorineural hearing loss and those with single-sided deafness.
Objective The aim of the present study was to evaluate the Ponto bone-anchored hearing system in terms of behavioral performance and self-reported outcomes, by comparing unaided and aided performance (softband and abutment), as well as aided performance with the sound processor on softband (preoperatively) versus abutment (postoperatively).
Methods Fourteen adult bone-anchored candidates, with either a bilateral (n = 12) or unilateral (n = 2) conductive or mixed hearing loss, participated in the present study. Sound-field hearing thresholds were evaluated unaided and aided (softband and abutment). A speech-in-noise test was also performed unaided and aided for two spatial configurations (S0N90; implanted side; S0N90; nonimplanted side). The Glasgow Health Status Inventory and the Speech, Spatial and Quality of sound questionnaires were administered pre- and postsurgery to compare quality of life and perceived unaided and aided performance. Skin reaction (Holgers scores) was evaluated at 15 days, 6 weeks, and 10 weeks after surgery.
Results Significant improvements postoperatively relative to unaided were obtained for sound-field thresholds at all tested frequencies. Additionally, sound-field thresholds were significantly improved with the sound processor on abutment relative to the softband at frequencies > 1 kHz. Improved performance postoperatively relative to unaided was also obtained in the speech-in-noise test and in self-reported outcomes.
Conclusions Improvements in behavioral performance and self-reported outcomes were obtained with the sound processor mounted on abutment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.