SummaryIn this paper, we discuss the reasons why we urgently need a point-of-care (POC) CD4 test, elaborate the problems we have experienced with the current technology which hampers CD4-count coverage and highlight the ideal characteristics of a universal CD4 POC test. It is high-time that CD4 technology is simplified and adapted for wider use in low-income countries to change the current paradigm of restricted access once and for all.
A study was conducted in rural Malawi to verify (a) whether the Partec CyFlow Counter((R)) for CD4+ T-cell lymphocyte counting in HIV-positive individuals could be introduced into a district hospital laboratory and (b) whether it would produce CD4 counts of acceptable quality. CD4+ cell counting was performed using the Partec CyFlow Counter and the results were compared with a reference method (FACsCount). A total of 311 blood samples were analysed and the correlation coefficient for the CyFlow Counter was 0.92 (95% CI 0.89-0.95). Mean CD4 counts using the Partec and the reference methods were 308.2 cells/microl and 316.9 cells/microl, respectively. The mean difference in CD4 count values was -8.68 cells/microl (95% CI -18.8 to 1.4). Mean intra-run variation was -6.84 cells/microl (95% CI -12.9 to 0.79). In the district laboratory setting, the instrument could accommodate up to 75 blood samples per technician per day. After being trained, local laboratory staff found the CyFlow Counter procedures simple to run and the instrument easy to manipulate. The Partec CyFlow Counter produces sufficiently reliable results and the instrument appears robust under field conditions. It could provide a new option for introducing routine CD4+ cell monitoring at the district level in the context of scaling-up antiretroviral therapy in Malawi.
) and a specificity of 97.8% (95% CI, 96.1 to 98.9%) using a 1,000-copies/ml cut point and a sensitivity of 83.0% (95% CI, 73.4 to 90.1%) and a specificity of 100% (95% CI, 99.3 to 100%) using a 5,000-copies/ml cut point. This study shows that FP-DBS is an acceptable alternative to plasma for measuring VL using the NucliSENS Easy-Q HIV-1 v2.0. We are conducting a second study to assess the proficiency of health workers at preparing FP-DBS in primary health care clinics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.