Asymptomatic leishmaniasis cases have continuously increased, especially among patients with HIV who are at risk to develop further symptoms of cutaneous and visceral leishmaniasis. Thus, early diagnosis using a simple, sensitive and reliable diagnostic assay is important because populations at risk mostly reside in rural communities where laboratory equipment is limited. In this study, the highly sensitive and selective determination of Leishmania infection in asymptomatic HIV patients was achieved using dual indicators (SYBR safe and gold-nanoparticle probe; AuNP-probe) in one-step LAMP method based on basic instruments. The assay can be simply evaluated under the naked eye due to clear interpretation of fluorescent emission of LAMP-SYBR safe dye-complex and colorimetric precipitate of specific AuNP-probes. The sensitivities and specificities of fluorescent SYBR safe dye and AuNP-probe indicators were equal, which were as high as 94.1 and 97.1%, respectively. Additionally, detection limits were 102 parasites/mL (0.0147 ng/µL), ten times more sensitivity than other related studies. To empower leishmaniasis surveillance, this inexpensive one-step SYBR safe and AuNP-LAMP assay is reliably fast and simple for field diagnostics to point-of-care settings, which can be set up in all levels of health care facilities including resource limited areas, especially in low to middle income countries.
In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase—and its cofactor—and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)−1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator’s mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.