The relevance of safety applications within the automotive industry is increasing continuously, for example due to vehicle automation and decreasing performance of mechanical backups. To cope with these trends, the power supply of safety-related electrical and/or electronic systems needs to be ensured. This leads to increasing functional safety requirements. Compliance with ISO 26262 will be more in focus in the future. Currently, the compliance with ISO 26262 may be used to argue the state of the art focusing on product liabilityhowever, it will become mandatory for homologation in the future. Thereby, the power supply system is a crucial point since faults of the power supply system are currently the major contributor for vehicle breakdowns with increasing tendency. So far, there is no standard approach within the automotive industry how to ensure functional safety for power supply systems. To fill this gap, this technical elaboration evaluates functional safety with focus on power supply system development. Hence, guidelines on how to apply the ISO 26262 are provided based on discussions within the automotive industry and research institutes. The focus is on the concept phase, i.e. item definition, hazard analysis and risk assessment, and the functional safety concept. The functional safety concept is based on a structured hierarchical breakdown to systematically derive safety requirements from the item level down to the power supply system level. The essential requirementbeside the safe power feed and safe power distributionis to assure the freedom from interference between the safety and non-safety relevant components.
The automotive industry is currently driven by the megatrends electrification, automated driving and connectivity. To cope with these trends, new functionalities and electrical and/or electronic (E/E) systems need to be developed and deployed. Independent of the implementation of E/E systems, their power input shall be ensured by the power supply system as a shared resource -leading to increased functional safety requirements for power supply systems. If the loss of an item's functionality can lead to a hazardous event, a safety goal (SG) specifying a safety-related availability (SaRA) requirement is derived. Thereby, switching to passive mode typically cannot be considered a safe state. To address an SG specifying a SaRA requirement, fault avoidance, fault forecasting and/or fault tolerance measures can be applied. In the case of fault tolerance measures implemented by redundancy, which leads to fail-active behavior, the performance of the backup system during nominal operation and after the first fault can be further refined. In this study, SaRA in the context of ISO 26262 is evaluated in detail and mapped to an example of the power supply domain.
The automotive industry is currently driven by the megatrends electrification, automated driving, and connectivity. To cope with these trends, new functionalities and electric and/or electronic systems must be developed, which require a safe power supply by the power supply system. This leads to increased functional safety requirements for the power supply system, particularly regarding availability. Fault tolerance measures can be implemented to address a safety goal specifying a safety-related availability requirement. In this case, emergency operation (EO) may be necessary to reach a defined safe state. The definitions and examples provided in ISO 26262 focus on cold redundancy, whereby the backup system is not engaged during nominal operation. The objective of this paper is to evaluate EO in the context of ISO 26262 in detail and map the results to an exemplary power supply system architecture implementing cold redundancy. In general, the EO is considered to be free from unreasonable risk even though the actual automotive safety integrity level (ASIL) capability of the item is lower than the initially specified ASIL rating for the hazard due to its timing restrictions. To determine the maximum permissible duration of EO, not just random hardware faults shall be considered; additionally, systematic effects shall be considered. Furthermore, an EO may be entered due to transient faults potentially causing temporary EOs -introducing the necessity of an EO recording, e.g. by accumulating the time of all temporary EOs.
To cope with the megatrends electrification, automated driving, and connectivity, new functionalities and E/E systems must be developed, which require a safe power supply. This leads to increased functional safety requirements for the power supply system, particularly regarding availability. Fault tolerance measures can be implemented to comply with an SG specifying a SaRA requirement. In this case, EO may be necessary to reach a defined safe state. However, there is some ambiguity in ISO 26262 regarding the necessary integrity with which the EO shall be implemented -this becomes in particular obvious in the case of warm redundancy. According to ISO 26262, the EO is entered once the failure of an element is controlled by an explicit fault handling, i.e., prevented from violating an SG, and the remaining ASIL capability of the item after the failure is lower than the required ASIL capability for the allowed VOS. However, in the context of warm redundancy, the EO can be automatically entered in the case of an element failure without an explicit fault handling. The objective of this paper is to transfer the concept of EO, as defined in ISO 26262, to warm redundancy use cases because warm-redundant power supply systems have a high level of market penetration. Besides a detailed evaluation of time dependencies, new guidelines concerning the required systematic integrity for SMs implementing EO are provided.
The ability of drugs to penetrate into cells and tissues is a fundamentally important property that is essential for the efficacy of drugs targeting intracellular processes. Many weakly basic small molecule drugs are known to accumulate extensively in acidic sub-cellular compartments such as lysosomes, through a process called ion trapping that is dependent on the physico-chemical properties of a compound. ‘Lysosomal uptake’ has been shown to significantly influence the activity of many agents, including anticancer drugs, both positively and negatively. Here we describe the unique physico-chemical properties of JNJ-42756493, a potent inhibitor of fibroblast growth factor receptors (FGFRs) 1, 2, 3 and 4, currently undergoing clinical testing for the treatment of malignancies with FGFR pathway activating alterations. JNJ-42756493 has weakly basic and lipophilic characteristics, is highly permeable, and is fluorescent when exposed to UV light. The fluorescent property of JNJ-42756493 enabled rapid and convenient visualization of the drug (spatial and temporal localization) within the lysosomes of cultured cells exposed to JNJ-42756493. In order to evaluate the influence of this lysosomotropic property on the activity of JNJ-42756493, FGFR phosphorylation was monitored in a series of wash-out experiments performed in various cellular models with FGFR1 or FGFR2 amplifications. This comparative washout analysis demonstrated prolonged FGFR kinase inhibition by JNJ-42756493 in comparison to other FGFR inhibitors lacking lysosomotropic properties. This qualitative fluorescence-based data was complemented by accurate quantification of the amount of compound taken up by the cells through the use of radiolabelled JNJ-42756493. Our results unequivocally demonstrate that JNJ-42756493 accumulates at high concentrations within the lysosomal compartment of cells without undergoing metabolism. The continued, long lasting effects on the target FGF receptor kinase inhibition following drug washout, suggest a novel intrinsic slow release of the unmodified drug from these intracellular stores. The lysosomotropic property of JNJ-42756493 is proposed to be a major contributor to the efficient and persistent inhibition of FGFR phosphorylation leading to potent cellular and in vivo activity. Citation Format: Eleonora Jovcheva, Caroline Paulussen, Patrick Van Bergen, Yolanda Chong, Jorge Vialard, Laurence Mevellec, Patrick Angibaud, Timothy Perera. Unique physicochemical properties of the potent FGFR 1, 2, 3 and 4 inhibitor JNJ-42756493 contribute to prolonged target shutdown. [abstract]. In: Proceedings of the 105th Annual Meeting of the American Association for Cancer Research; 2014 Apr 5-9; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2014;74(19 Suppl):Abstract nr LB-233. doi:10.1158/1538-7445.AM2014-LB-233
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.