Background-The cardiac output (CO) response to exercise and other invasively derived hemodynamic variables has been variably described to provide better prognostication than peak VO 2 in patients with chronic heart failure. Using noninvasive measurements of CO during exercise, we compared the prognostic value of peak CO and cardiac power to peak VO 2 in chronic heart failure patients. Method and Results-One hundred seventy-one consecutive patients with chronic heart failure underwent symptom limited bicycle exercise with noninvasive estimation of CO using an inert gas rebreathing method. An accurate measure of peak CO was obtained in 148 patients (85% of patients; mean age, 53Ϯ14 years; 80% male; left ventricular ejection fraction, 24Ϯ12%; ischemic etiology, 34%). Peak cardiac power was derived from the product of the peak mean arterial blood pressure and CO divided by 451. End points consisted of death, urgent heart transplant, or left ventricular assist device implantation. Duration of follow-up averaged 337Ϯ252 days (median, 295 days). Univariate and multivariate analysis were performed. The variables analyzed included peak VO 2 , peak CO, peak cardiac power, VE/VCO 2 slope, and VO 2 at anaerobic threshold. Event-free survival for the entire cohort was 83% with 5 deaths, 4 left ventricular assist device implants, and 16 urgent transplants. Peak VO 2 was 12.9Ϯ4.5 mL/kg per min, and peak cardiac power was 1.7Ϯ0.9 W. Peak VO 2 , peak CO, peak cardiac power, VE/VCO 2 slope, and VO 2 at anaerobic threshold were predictive of outcome on univariate analysis. On multivariate analysis, peak cardiac power and peak CO were predictive of outcome with peak cardiac power being the most powerful independent predictor of outcome (Pϭ0.01). Conclusions-Peak cardiac power, measured noninvasively, is an independent predictor of outcome that can enhance the prognostic power of peak VO 2 in the evaluation of patients with heart failure. (Circ Heart Fail. 2009;2:33-38.)
A prospective, open label, 3 month study was conducted to evaluate the feasibility and short term clinical effect of subcutaneous erythropoietin injections in patients with anemia and heart failure preserved ejection fraction (HFPEF; EF=55±2). Using a dose adjusted algorithm to affect a rate of rise in hemoglobin not to exceed 0.4 g/dL per week, hemoglobin (10.8±0.3 to 12.2±0.3 gm/dl) and red blood cell volume (1187±55 to 1333±38 ml) increased with an average weekly dose 3926 units. Functional measures increased from baseline [6 minute walk test (289±24 to 331±22 meters), exercise time (432±62 to 571±51 seconds) and peak VO2 (8.2±0.7 to 9.4±0.9 ml/kg/min)], all p<0.05. EDV declined significantly (8% volumetric decrease, 108±3 to 100±3 ml, p = 0.03) but there were no significant changes in LV mass or estimated LVEDP. Pressure volume analysis demonstrated a reduction in V30 (e.g. ventricular capacitance) without significant changes in contractile state.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.