Abstract-Analytical calculation methods for all the major components of the synchronous inductance of tooth-coil permanentmagnet synchronous machines are reevaluated in this paper. The inductance estimation is different in the tooth-coil machine compared with the one in the traditional rotating field winding machine. The accuracy of the analytical torque calculation highly depends on the estimated synchronous inductance. Despite powerful finite element method (FEM) tools, an accurate and fast analytical method is required at an early design stage to find an initial machine design structure with the desired performance. The results of the analytical inductance calculation are verified and assessed in terms of accuracy with the FEM simulation results and with the prototype measurement results.Index Terms-Fractional slot winding, inductance calculation, leakage inductance, permanent-magnet synchronous machine (PMSM), tooth coil.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.