A characteristic notch in the heart rate (fc) on-response at the beginning of square-wave exercise is described in 7 very fit marathon runners and 12 sedentary young men, during cycle tests at 30% and 60% of maximal oxygen consumption (VO2max). The fc notch revealed a fc overshoot with respect to the fc values predicted from exponential beat-by-beat fitted models. While at 30% of VO2max all subjects showed a fc overshoot, at 60% of VO2max it occurred in the marathon runners but not in the sedentary subjects. The mean time of occurrence of the fc overshoot from the onset of the exercise was 16.7 (SD 4.7) s and 12.2 (SD 3.2) s at 30% of VO2max in the runners and the sedentary subjects respectively, and 23.8 (SD 8.8) s at 60% of VO2max in the runners. The amplitude of the overshoot, with respect to rest, was 41 (SD 12) beats.min-1 and 31 (SD 4) beats.min-1 at 30% of VO2max in the runners and the sedentary subjects respectively, and 46 (SD 19) beats.min-1 at 60% of VO2max in the runners. The existence and the amplitude of the fc overshoot may have been related to central command and muscle heart reflex mechanisms and thus may have been indicators of changes in the balance between sympathetic and parasympathetic activity occurring in fit and unfit subjects.
The four-electrode electrical impedance measurement technique is proposed for the evaluation of the hyperaemia variation in tissues treated by diathermic therapy. An impedance meter suitable for such measurements is described, and an electrical model of the heated tissues, concerning the impedance variation during diathermy and its relation with hyperaemia, is presented. The occurrence of the substantial contribution of blood to the overall transverse impedance is demonstrated by comparing the experimental results with those arising from a 2D electrical/thermal model of the treated tissues. A two-admittance model is proposed to explain the electrical behaviour of the tissues treated by diathermy. The model allows us to separate the impedance violation due to the temperature dependence of tissue conductivity from that due to the change of tissue blood content. The results of preliminary measurements of tissue impedance on healthy volunteers treated by electromagnetic diathermy are presented and discussed, showing the feasibility of impedance detection of hyperaemia variations inside tissues.
The short course of brachytherapy provides a good palliation in terms of functional improvement in a high proportion of patients, with low and acceptable toxicity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.