The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.
Treatment of hyperopia using the sixth-generation Amaris excimer laser provides good results in terms of efficacy, safety, predictability, and visual outcomes after 3 years. The refractive stability shows a significant regression in the first 12 months after surgery with more stable results from 12 months postoperatively.
Purpose: To evaluate the clinical and visual outcomes, quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens (IOL). Methods: In this prospective consecutive case series, 20 eyes of 10 patients were included (mean age 63.80 ± 12.55 years). Uncorrected and corrected visual acuity (far, intermediate and near), subjective refraction, binocular defocus curve, contrast sensitivity (CSV-1000) and quality of vision and satisfaction questionnaires were measured. The follow-up was 12 months after surgery. Results: At 12 months after surgery, uncorrected distance visual acuity (UDVA) improved with surgery (p = 0.001) with a value of 0.08 ± 0.08 logMAR. Uncorrected near visual acuity (UNVA) was 0.22 ± 0.12 logMAR and distance corrected near visual acuity (DCNVA) was 0.16 ± 0.13 logMAR. Intermediate distance visual acuity (UIVA) was 0.22 ± 0.10 logMAR. Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting. Defocus curve showed that this multifocal IOL was able to provide a visual acuity (VA) equal or better to 0.16 logMAR between defocus levels of + 1.00 to − 2.50 D. Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes. Conclusions: The Precizon Presbyopic NVA IOL (OPHTEC BV) provides good visual outcomes. This multifocal IOL provides a high percentage of spectacle independence due to good VA at far, intermediate and near distances and satisfactory contrast sensitivity. High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
Purpose: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. Methods: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). Results: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 ± 0.12 and 0.31 ± 0.07, respectively), followed by the AcrySof SA60AT (0.39 ± 0.10 and 0.27 ± 0.07) and AcrySof IQ Vivity (0.34 ± 0.11 and 0.24 ± 0.09) ( P < .001). The AcrySof IQ Vivity and monofocal IOLs were comparable ( P > .05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 ± 0.06 at 3 mm; P < .001) compared to the monofocal AcrySof SA60AT (0.24 ± 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 ± 0.06 at 3 mm) groups. The PSF with LOA was comparable ( P > .05) among the three groups at both the 3-and 4-mm pupil size. Conclusions: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and mono-focal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA). [ J Refract Surg . 2023;39(2):103–110.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.