This paper describes changes to specimen grips and specimen design in order to creep test steels at temperatures a little below the spalling temperature and at low stresses (long times) where a large amount of oxidation occurs. High ductility and oxidation of a creep specimen often mean that the thermocouples lose contact with the specimen surface and the specimen itself cannot be removed from the grips after testing. The improvements involve the use of corrosion resistant alloys with reasonable high temperature strength for the loading bars and grips, a change in grip design and measuring the temperature inside the specimen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.