Objective: To evaluate the accuracy of different parameters of the ophthalmic artery Doppler (OAD) in the complementary diagnosis of preeclampsia (PE). Methods: This meta-analysis adhered to the PRISMA guidelines. To investigate the mean difference in OAD values, peak systolic velocity (PSV), end-diastolic velocity (EDV), second systolic velocity peak (P2), resistance index (RI), pulsatility index (PI), and peak ratio (PR), between PE cases (overall and according to severity) and controls, random-effects meta-analyses were conducted for each Doppler parameter, with overall PE and mild and severe PE subgroups. Diagnostic performance and heterogeneity were evaluated with summary receiver operating characteristic (sROC) curves and 95% confidence intervals obtained with bivariate models. Results: Eight studies stratified the results into mild and severe or late and early PE, involving 1,425 pregnant women. PR and P2 had better diagnostic performance than the other indexes, with the PR of AUsROC at 0.885, the sensitivity of 84%, and specificity of 92%, with a low false-positive rate of 0.08 and the P2 with AUsROC of 0.926, the sensitivity of 85% and specificity of 88%. RI, PI, and EDV showed good performance and consistency across studies but lower AUsROC values of 0.833, 0.794, and 0.772, respectively. Conclusion: Ophthalmic artery Doppler is a complementary tool with good performance for the diagnosis of overall and severe preeclampsia, with high and best sensitivity and specificity when using PR and P2 parameters.
Objective: To evaluate the accuracy of different parameters of the ophthalmic artery Doppler (OAD) in the complementary diagnosis of preeclampsia (PE).Methods: To investigate the mean difference in OAD values, peak systolic velocity (PSV), end-diastolic velocity (EDV), second systolic velocity peak (P2), resistance index (RI), pulsatility index (PI), and peak ratio (PR), between PE cases (overall and according to severity) and controls, random-effects meta-analyses were conducted for each Doppler parameter, with overall PE, mild and severe PE subgroups. Diagnostic performance and heterogeneity were evaluated with summary receiver-operating characteristics curves (sROC) and 95% confidence regions, obtained with bivariate modelsResults: Eight studies stratified the results in mild and severe or late and early PE, involving 1,425 pregnant women. PR and P2 had better diagnostic performance than the other indexes, with the PR of AUsROC at 0.885, the sensitivity of 84%, and specificity of 92%, with a low false-positive rate of 0.08 and the P2 with AUsROC of 0.926, the sensitivity of 85% and specificity of 88%. RI, PI, and EDV showed good performance and consistency across studies, but lower AUsROC of 0.833, 0.794, and 0.772, respectively.Conclusion: Ophthalmic artery Doppler is a complementary tool with good performance for diagnosis of overall and severe preeclampsia, with high and best sensitivity and specificity when using PR and P2 parameters.
Objective To evaluate the accuracy of different parameters of the ophthalmic artery Doppler (OAD) in the complementary diagnosis of preeclampsia (PE). Methods This meta-analysis adhered to the PRISMA guidelines. To investigate the mean difference in OAD values, peak systolic velocity (PSV), end-diastolic velocity (EDV), second systolic velocity peak (P2), resistance index (RI), pulsatility index (PI), and peak ratio (PR), between PE cases (overall and according to severity) and controls, random-effects meta-analyses were conducted for each Doppler parameter, with overall PE and mild and severe PE subgroups. Diagnostic performance and heterogeneity were evaluated with summary receiver operating characteristic (sROC) curves and 95% confidence intervals obtained with bivariate models. Results Eight studies stratified the results into mild and severe or late and early PE, involving 1,425 pregnant women. PR and P2 had better diagnostic performance than the other indexes, with the PR of AUsROC at 0.885, the sensitivity of 84%, and specificity of 92%, with a low false-positive rate of 0.08 and the P2 with AUsROC of 0.926, the sensitivity of 85% and specificity of 88%. RI, PI, and EDV showed good performance and consistency across studies but lower AUsROC values of 0.833, 0.794, and 0.772, respectively. Conclusion Ophthalmic artery Doppler is a complementary tool with good performance for the diagnosis of overall and severe preeclampsia, with high and best sensitivity and specificity when using PR and P2 parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.