Lu-Sn colloid was successfully prepared with a high LE (>95%) and high RCP (99%) under optimized reaction conditions. Because of the numerous benefits of Lu and the ease of preparation of tin colloid particles, Lu-Sn colloid particles are significantly superior to its currently available counterparts for use in radiosynovectomy.
Lu tin colloid synovectomy is a useful treatment modality in patients with chronic inflammatory knee joint conditions refractory to conventional treatment. Patients with shorter duration of disease and normal or minor radiographic findings are better candidates for RSV.
Metastasis to the breast is a rare occurrence and constitutes less than 2% of all breast tumors. Similarly, ovarian metastases from neuroendocrine tumors are also uncommon, and if the adnexal masses are bilateral, then the chances of it being metastatic rather than being primary range from 88% to 94%. We present a case of 61-year-old woman who in the course of workup for abdominal pain and diarrhea was eventually diagnosed as ileal neuroendocrine tumor with breast, ovarian, and lymph nodal metastases on 68Ga-DOTANOC PET/CT scan.
Objective
To assess the role of Lutetium-177(Lu-177) tin colloid for radiosynovectomy and compare it with Rhenium-188 (Re-188) tin colloid radiosynovectomy for alleviation of pain in patients with chronic inflammatory arthritis of knee.
Methods
Patients of chronic inflammatory arthritis of the knee underwent pretherapeutic evaluation in a form of knee ultrasonogram, bone scan and clinical evaluation. Fifty-seven recruited patients were allocated at random to receive either intraarticular injections of Lu-177 tin colloid or Re-188 tin colloid. Eventually, 27 patients received Re-188 tin colloid and 30 patients received Lu-177 tin colloid. The joint was then immobilized for 2 days. Response evaluation was done using knee ultrasound, bone scan and clinical findings.
Result
Of 30, 20 patients responded to radiosynovectomy in the Lu-177 tin colloid group compared to 21/27 patients in the Re-188 tin colloid group.
Conclusion
Lu-177 tin colloid is an effective alternative to Re-188 tin colloid for radiosynovectomy in patients with chronic inflammatory knee arthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.