Piles should possess the structural integrity to carry the design load and transfer to the soil/rock below. As per Indian standard IS 14893:2001, in general following defects are observed in the pile, which may lead to catastrophic failure. (a) Pile shaft necking, (b) Discontinuity of concrete, (c) Intrusion of foreign matter, (d)Improper toe formation due to contamination of concrete at the base with soil particles, (e) Washing of concrete due to high water current, and (f) Poor quality control with improper construction methods. NDT-based low strain pile integrity testing can be effectively used for evaluation of quality and acceptance of pile foundations. Low strain pile integrity test is based on pulse echo method. Pile integrity tester gives the velocity plot versus time. The plot is observed for the reflections, which indicate the change in the property of wave passing medium. The reflections may be due to soil resistance (stiffness) effects, cross-sectional changes, and soil property changes. In this study, bored cast-in-situ piles are evaluated for its integrity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.