Portal biliopathy was reversed in 38 of 43 patients by either portosystemic shunting or splenectomy-devascularization. In five patients, direct biliary decompressive procedures were required because of shunt blockage or a non-reversible biliary stricture.
This study provides preliminary laboratory evidence indicating the ability of homeopathic medicines as anticancer agents. Further studies of the action of these homeopathic remedies are warranted.
Background:
This study evaluated the efficacy of spinal anesthesia administration by resident physicians when using an ultrasound system with automated neuraxial landmark detection capabilities.
Methods:
150 patients were enrolled in this trial. Anesthesiology residents placed spinals in subjects undergoing scheduled cesarean delivery using one of three techniques to identify neuraxial landmarks: palpation, ultrasound, or combined palpation and ultrasound. Ultrasound was performed using a handheld system that automatically identified neuraxial landmarks (e.g. midline, intervertebral spaces). All residents watched a 10-minute video and received 20 minutes of hands-on training prior to participating in the study. First insertion success rate was the primary end point.
Results:
Among all patients, use of ultrasound resulted in a 11% greater first-insertion success rate (RR: 1.11 [0.85–1.47], p=0.431), a 15% reduction in needle insertions (RR: 0.85, p=0.052), and a 26% decrease in needle passes (RR: 0.74, p=0.070). In obese patients of BMI ≥ 30 kg/m
2
, use of ultrasound resulted in 26% greater first-insertion success rates (RR: 1.26, p=0.187), a 21% decrease in needle insertions (RR: 0.79, p=0.025), a 38% decrease in needle passes (RR: 0.62, p=0.030), and a 75% decrease in patients reporting neutral or low patient satisfaction with anesthesia administration (RR: 0.25, p=0.004).
Discussion:
Resident anesthesiologists competently utilized the ultrasound system after receiving minimal training. Technical endpoints and patient satisfaction trended towards improvement when ultrasound was used prior to spinal placement, with stronger trends observed in obese patients. Additional study is required to fully characterize the impact of the ultrasound system on clinical efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.