BACKGROUND AND PURPOSE:The signal intensity of the thyroid in neonates is high on T1WI. It is affected by gestational and postnatal ages. However, the extent of the influence of these ages is unknown. This study investigated the relationship of signal intensities of the infant thyroid with postnatal and gestational ages and anterior pituitary using 3D gradient-echo T1WI.
MATERIALS AND METHODS:This retrospective study included 183 T1-weighted images from 181 infants. Using a multiple linear regression analysis, we evaluated the effects of postnatal and gestational ages on the thyroid-muscle signal intensity ratio. The relationship between the thyroid and anterior pituitary signal intensities on T1WI and the age of the infants was evaluated.RESULTS: Multiple linear regression analysis showed that the thyroid signal intensity was affected negatively by postnatal age at examination and positively by gestational age at birth (P , .01 and P ¼ .04, respectively). According to the standardized partial regression coefficients, the influence of postnatal age at examination was stronger than that of gestational age at birth (À0.72 and 0.13, respectively). The thyroid and anterior pituitary signal intensities reached constant values at 12 weeks' postnatal age, and the mean thyroid-anterior pituitary signal intensity ratios were almost 1 throughout the entire period.
CONCLUSIONS:The signal intensity of the infant thyroid on T1WI was more strongly influenced by the postnatal age at examination than the gestational age at birth, and it was almost equal to that of the anterior pituitary.
Stent-graft placement is an important treatment for traumatic renal artery dissection, but it may occasionally be technically difficult to advance a catheter through the lesion of the dissection due to severe stenosis of the true rumen. A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has recently become available, and it contributes to super-selective catheterization. We thought this system may be useful for passing catheters through the dissection. We herein report a 30-year-old male patient with traumatic renal artery dissection, who was successfully treated by stent-graft placement using the triaxial system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.