This paper aims to analyse the performance of impedance pump that uses energy mismatch to drive fluid flow. The experimental setup mainly focus to establish the relationship between the fluids flow rates in elastic tube section connected between two ends of solid tube and pinch mechanism location as well as fluid viscosity. Measurement of fluid flow rate or representation of its velocities resulting from the pumping mechanism is measured using two different supply voltage and constant pincher width. These measured parameters resulting from the pinch mechanism of the elastic tube section were varied at different pinch location along itsx-axis direction; divided into two main cases namely (1) 2 V and (2) 3 V at 40 mm to 140 mm pinch location. From the voltage variation, it is found that the maximum flow rate given by voltage 3.0 V at pinch location 40 mm while for the effect of viscosity, the highest flow rate is 93 ml/min. The profiles obtained revealed the characteristic of valve less pump to be the new model of new Ventricular Assist Device use in cardiac patient as well as further explanation about the factor that influence the characteristic of elastic tube.
Impedance pump is a simple valveless pumping mechanism which typically used in viscosity measurement device to assist pumping of fluid. It is typically connected to an elastic tube in a circulatory system of a more rigid tube. In conventional mechanical circulatory support systems using rotary pump, the pumping mechanism was exposed to turbulent stresses. Hence, this may cause damage to blood cells flowing through the impeller. There has been initial work on finding alternative solution using the impedance pump system. However, substantial findings are not yet sufficient to fully understand the mechanism. The purpose of this research is to extend the investigation on impedance pump by specifically looking at the effect of structural parameters on the elastic tube and the flow behaviour. In this study, a closed loop impedance pump system was set up to demonstrate blood flow circulatory system where the mixture of glycerine and water was used as the working fluid. Three variables were regulated namely voltage, tube thickness, and tube length was used in order to get the flowrate of the working fluid. Based on the results, it was found that tube thickness of 1 mm and a length of 200 mm had produced the highest flowrate in the region 75 ml/min.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.