Factor VIII (FVIII) concentrates have revolutionized the treatment of patients with haemophilia A. Concerns over the transmission of viral infections through these products have been addressed through stringent, donor-screening procedures and robust antiviral manufacturing steps. Bio Products Laboratory has developed a high-purity FVIII product with von Willebrand factor, Optivate(®). Its safety, tolerability and efficacy as prophylaxis and treatment of bleeds have been established in long-term studies. Seventy previously treated patients with severe haemophilia A, with ≥ 20 exposure days, were recruited into two long-term, multicentre, open-label studies. The protocols were virtually identical. Patients received Optivate(®) either prophylactically or on-demand. A mean of 159.0 EDs were experienced over 11,320 infusions. Under both conditions, Optivate(®) was well tolerated. Only 10% of patients experienced a treatment-related adverse event; the most commonly reported were headache (4% of patients) and dizziness (3% of patients). The mean number of bleeds/patient over the 2 year treatment period was 23.5 during prophylactic use and 70.4 during on-demand use. In patients treated prophylactically, clinical responses to breakthrough bleeds were rated by physicians as excellent or good and as very helpful or helpful by patients in 95% of bleeds. Clinical responses for on-demand patients were rated as excellent or good by physicians and helpful or very helpful by the patients for 91% of bleeds. There were no viral transmissions or inhibitors. The studies confirm the clinical efficacy and safety of Optivate(®) in both prophylactic and on-demand management of patients with haemophilia A.
Optivate(®) is a high purity factor VIII/von Willebrand factor (FVIII/VWF) concentrate, which is manufactured using two antiviral processes: solvent/detergent and terminal dry heating (80 °C for 72 h). A multicentre, non-randomized open-label study in 15 patients was conducted to test the pharmacokinetics (PK) of Optivate(®). PK variables were analysed for the patients' prior FVIII product (PK1), their first dose of Optivate(®) (PK2) and at 3 months therapy (PK3). Mean non-compartmental half-lives (h) were 14.1, 12.4 and 12.1, respectively (P = 0.45), mean clearances (mL h(-1) kg(-1)) were 3.6, 3.2 and 3.1, respectively (P = 0.051), MRTs (h) were 19.0, 17.3 and 17.4, respectively (P = 0.39) and mean AUC(0-48h) (h IU mL(-1)) were 14.3, 15.4 and 16.6, respectively (P = 0.051) and mean AUC(0-∞) (h IU mL(-1)) were 15.9, 16.4 and 17.9, respectively (P = 0.18). The recovery data from this PK study was aggregated with recovery data collected from another study, with similar design but devoid of the other PK measurements. A total of 309 recoveries were conducted in 70 patients. The overall mean recovery per subject across 27 Optivate(®) batches was 2.7 IU dL(-1) per IU kg(-1). There were no clinical differences between Optivate(®) and other FVIII products, and except for volume of distribution (Vd), no statistically significant differences were seen with respect to any of the other PK variables, or in recovery between weeks 0 and 12. Therefore, the PK of FVIII is not affected by the processes used to manufacture Optivate(®), which can be expected to be effective in the management of patients with haemophilia A.
The efficacy and safety of Optivate(®) was assessed in 23 surgical operations, orthopaedic (12) including 5 revision arthroplasties, ophthalmic (1), ENT (1), dental (6), liver biopsy (2), and removal of portacath (1) on 15 teenagers and adults with severe haemophilia A. The preoperative dose was calculated to raise the FVIII concentration to 100 IU dL(-1). Subsequent doses were targeted to maintain at least 50 IU dL(-1). There were 11 major and 12 minor operations categorized as receiving intensive replacement therapy for ≥ 5 days or < 5 days respectively. The median preoperative dose was 50.4 (range 18.2-88.2) IU kg(-1). The median incremental recovery based on this first dose in 10 procedures (5 patients) was 2.9 (range 2.4-3.4 IU dL(-1) ) per IU kg(-1). The daily doses decreased during the first 4 days of the study. The patients in this study received 173 infusions in total. Outcome was 'good' or 'excellent' for 19 (83%) of 23 operations, 'uncertain' in three procedures because an antifibrinolytic agent was used as well and for one procedure outcome was not assessed. Tolerance was good. There were no excessive bleeds, no inhibitors and no virus transmissions.
Optivate® is a high-purity FVIII/VWF product. Its safety, tolerability and efficacy in subjects ≥ 12 years have been demonstrated. This study was undertaken to assess Optivate® in children with haemophilia A. Twenty-five children, including one PUP (previously untreated patient), aged 1-6 years (mean 4.67 years) were treated with Optivate® for 26 weeks. Inhibitors were assessed every 3 months and viral status at the study start and end. Prophylaxis was used by five boys and on demand by twenty. The mean number of bleeds in the study was lower compared to the same period pre-study (12.0/child vs. 16.2/child), with fewer bleeds (P < 0.05) in the prophylactic subgroup (8.0/child) compared with the on-demand sub-group (13.4/child). Fourteen major bleeds were reported, all by the on-demand sub-group. Children on prophylaxis were administered a mean of 59.4 infusions; on-demand group 35.1 infusions. A total of 998 infusions were used with a mean dose of 29.1 IU kg⁻¹, and a mean of 38.6 exposure days (ED). Children < 4 years used higher doses, and reported fewer bleeds than older children. Children's Parents/Guardians rated Optivate® as helpful or very helpful in controlling 97.5% of bleeds by the prophylactic group, and in 98.5% of the bleeds in the on-demand group. Only 5 of 101 ADRs were treatment-related events (5%), all were mild and non-serious. There were no clinically significant changes in vital signs, viral transmissions or inhibitors. In young children Optivate® was well tolerated, safe and efficacious.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.