This paper reviews experimental as well as computational techniques for determining stress-strain characteristics of materials at high strain rates. Quasi-static and dynamic compression tests were performed on standard Lead (Pb) specimens of three different L/D ratios, 0.8, 2 and 3. A Drop tower system was used to achieve different strain rates along with high-speed camera to capture the vertical and radial deformation of specimen and accelerometers to capture load data. The results obtained from the experiments were processed to generate dynamic stress-strain curve for Lead under different strain rate conditions. It was observed that the dynamic stress increases with increasing strain rate. The information gained is valuable for validating constitutive models.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.