Introduction:Apart from the visual assessment, measurement of plasma hemoglobin in the supernatant from red cell units provides an objective measure of the extent of hemolysis during storage.Study Design and Methods:Packed red cells (N=50), 25 units each in triple (CPD-A1 and SAGM) and quadruple (CPD-A1 and ADSOL) blood bags were evaluated for plasma hemoglobin by the tetramethylbenzidiene (TMB) method on day 1, 7, 14, 21 and 28 of collection. The hemoglobin, hematocrit, MCV, LDH and potassium levels were also noted. Whole blood units (N=25) were used as controls.Results:Hemolysis increased in all the stored red cell units. Plasma hemoglobin increased significantly in the first week of storage. The hemolysis, LDH and potassium levels were found to be significantly higher in the red cell units harvested from the triple blood bags. However, on day 28 of storage, free hemoglobin in all the red cell units was much below the 0.8% hemolysis.Conclusion:Hemolysis of the red cells increases due to processing and during storage and is maximum during the first week. Adequate process control and proper storage facilities should be ensured to minimize the hemolysis of red cells during processing and storage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.