Deep vein thrombosis (DVT) of the lower extremities can be associated with significant morbidity and may progress to pulmonary embolism and postthrombotic syndrome. Early diagnosis and treatment are important to minimize the risk of these complications. We systematically reviewed the accuracy of diagnostic tests for first-episode and recurrent DVT of the lower extremities, including proximal compression ultrasonography (US), whole leg US, serial US, and high-sensitivity quantitative D-dimer assays. We searched Cochrane Central, MEDLINE, and EMBASE for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. Two investigators screened and abstracted data. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 43 studies. For any suspected DVT, the pooled estimates for sensitivity and specificity of proximal compression US were 90.1% (95% confidence interval [CI], 86.5-92.8) and 98.5% (95% CI, 97.6-99.1), respectively. For whole-leg US, pooled estimates were 94.0% (95% CI, 91.3-95.9) and 97.3% (95% CI, 94.8-98.6); for serial US pooled estimates were 97.9% (95% CI, 96.0-98.9) and 99.8% (95% CI, 99.3-99.9). For D-dimer, pooled estimates were 96.1% (95% CI, 92.6-98.0) and 35.7% (95% CI, 29.5-42.4). Recurrent DVT studies were not pooled. Certainty of evidence varied from low to high. This systematic review of current diagnostic tests for DVT of the lower extremities provides accuracy estimates. The tests are evaluated when performed in a stand-alone fashion, and in a diagnostic pathway. The pretest probability of DVT often assessed by a clinical decision rule will influence how, together with sensitivity and specificity estimates, patients will be managed.
The findings have demonstrated that early transient sphingosine‐1 phosphate lyase inhibition after acute myocardial infarction (AMI) correlates with increased stem cell mobilization and homing to the infarct border zones. These data indicate that pharmacological elevation of bioactive lipid levels can be beneficial in the early phase after cardiac ischemic injury and provide the first evidence that carefully timed transient pharmacological upregulation of bioactive lipids after AMI could be therapeutic.
Pulmonary embolism (PE) is a common, potentially life-threatening yet treatable condition. Prompt diagnosis and expeditious therapeutic intervention is of paramount importance for optimal patient management. Our objective was to systematically review the accuracy of D-dimer assay, compression ultrasonography (CUS), computed tomography pulmonary angiography (CTPA), and ventilation-perfusion (V/Q) scanning for the diagnosis of suspected first and recurrent PE. We searched Cochrane Central, MEDLINE, and EMBASE for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. 2 investigators screened and abstracted data. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 61 studies. The pooled estimates for D-dimer sensitivity and specificity were 0.97 (95% confidence interval [CI], 0.96-0.98) and 0.41 (95% CI, 0.36-0.46) respectively, whereas CTPA sensitivity and specificity were 0.94 (95% CI, 0.89-0.97) and 0.98 (95% CI, 0.97-0.99), respectively, and CUS sensitivity and specificity were 0.49 (95% CI, 0.31-0.66) and 0.96 (95% CI, 0.95-0.98), respectively. Three variations of pooled estimates for sensitivity and specificity of V/Q scan were carried out, based on interpretation of test results. D-dimer had the highest sensitivity when compared with imaging. CTPA and V/Q scans (high probability scan as a positive and low/non-diagnostic/normal scan as negative) both had the highest specificity. This systematic review was registered on PROSPERO as CRD42018084669.
Background: We investigate whether deep learning (DL) neural networks can reduce erroneous human "judgment calls" on bedside echocardiograms and help distinguish Takotsubo syndrome (TTS) from anterior wall ST segment elevation myocardial infarction (STEMI). Methods: We developed a single-channel (DCNN[2D SCI]), a multi-channel (DCNN[2D MCI]), and a 3-dimensional (DCNN[2D+t]) deep convolution neural network, and a recurrent neural network (RNN) based on 17,280 still-frame images and 540 videos from 2-dimensional echocardiograms in 10 years (1 January 2008 to 1 January 2018) retrospective cohort in University of Iowa (UI) and eight other medical centers. Echocardiograms from 450 UI patients were randomly divided into training and testing sets for internal training, testing, and model construction. Echocardiograms of 90 patients from the other medical centers were used for external validation to evaluate the model generalizability. A total of 49 board-certified human readers performed human-side classification on the same echocardiography dataset to compare the diagnostic performance and help data visualization. Findings: The DCNN (2D SCI), DCNN (2D MCI), DCNN(2D+t), and RNN models established based on UI dataset for TTS versus STEMI prediction showed mean diagnostic accuracy 73%, 75%, 80%, and 75% respectively, and mean diagnostic accuracy of 74%, 74%, 77%, and 73%, respectively, on the external validation. DCNN(2D+t) (area under the curve [AUC] 0¢787 vs. 0¢699, P = 0¢015) and RNN models (AUC 0¢774 vs. 0¢699, P = 0¢033) outperformed human readers in differentiating TTS and STEMI by reducing human erroneous judgement calls on TTS. Interpretation: Spatio-temporal hybrid DL neural networks reduce erroneous human "judgement calls" in distinguishing TTS from anterior wall STEMI based on bedside echocardiographic videos.
Upper extremity deep vein thrombosis (UEDVT) accounts for ≤10% of DVT and can be associated with morbidity and mortality. Accurate diagnosis and treatment are necessary for safe and effective patient management. We systematically reviewed the accuracy of D-dimer and duplex ultrasonography (US) for the evaluation of suspected first-episode UEDVT. We searched the Cochrane Central Register, OVID MEDLINE, EMBASE, and PubMed for eligible studies, reference lists of relevant reviews, registered trials, and relevant conference proceedings. We included prospective cross-sectional and cohort studies that evaluated test accuracy. Two investigators independently screened and collected data. The risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies 2 and certainty of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework. We pooled estimates of sensitivity and specificity. The review included 9 studies. The pooled estimates for D-dimer sensitivity and specificity were 0.96 (95% confidence interval [CI], 0.87-0.99) and 0.47 (95% CI, 0.43-0.52), respectively. The pooled estimates for duplex US sensitivity and specificity were 0.87 (95% CI, 0.73-0.94) and 0.85 (95% CI, 0.72-0.93), respectively. Certainty of evidence was moderate. In this review, we summarized the test accuracy (sensitivity and specificity) of D-dimer and duplex US for this indication. The sensitivity and specificity of the tests found in the present review should be considered in the context of whether they are used alone or in combination, which is dependent on the prevalence of disease in the population, the clinical setting in which the patient is being evaluated, cost, potential harms, and patient outcomes. This study was registered at PROSPERO as Systematic Review Registration Number CRD42018098488.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.