Protocols have been developed and applied for the generation of aerosols that are likely to be comparable to those encountered in field settings for the calibration of easily transportable/portable real-time particle monitors. Aerosols generated were simulated environmental tobacco smoke, cedar wood smoke, cooking oil fumes, and propane stove particles. The time-integrated responses of three nephelometers and a monitor for particle-bound polynuclear aromatic hydrocarbons (PAH) were compared with gravimetric respirable suspended particulate matter (RSP) in a controlled-atmosphere chamber. In general, the monitor responses increased linearly with increasing mass concentration. However, the two monitors that reported mass per volume concentrations tended to overreport the actual RSP concentrations by factors up to 4.4. The real-time PAH monitor did not respond to cooking oil fumes, indicative of little PAH being present in the aerosol. One of the monitors that has been used in a variety of studies reported in the literature (DustTrak) was collocated with gravimetric RSP samplers in several hospitality venues in the Louisville, KY, area. Field studies indicated that the units overreported actual RSP concentrations by factors of 2.6 -3
A gas chromatographic method utilizing thermal desorption of Tenax TA and sol-gel sorbent traps has been developed and validated for the analysis of trace explosive vapor with negative ion chemical ionization mass spectrometric detection. Sorbent tubes were packed with Tenax TA and sorbent particles prepared in-house by the sol-gel process. Thermal desorption was performed within a split/splitless injection port with minimal instrument modification. Performance was characterized by relative thermal desorption recovery, precision (reproducibility), linearity of the calibration, and method detection limits. Method validation was performed with a series of dinitrotoluenes, dinitrobenzene, trinitrotoluene, trinitrobenzene, two aminodinitrotoluenes, three nitroesters, and two nitramines. The performance of Tenax TA and the sol-gel sorbents is evaluated based on the method validation data. The method was applied to the analysis of trace explosive vapor collected and concentrated with sol-gel solid sorbent traps from the headspace of a smokeless gunpowder sample.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.