. Intraocular pressure values of preoperative and postoperative first day, first week and first month visits were recorded. Intraocular pressures over 22 mm Hg were considered as high IOP. Either anterior chamber decompression or antiglaucomatous medication was used to decrease the postoperative rise in IOP. Changes in IOP were analyzed using ANOVA. R Re es su ul lt ts s: : The mean preoperative IOP was 15.6±4.3 mmHg, which increased to 19.7±9.0 mmHg on the 1st day (p<0.001). The IOP decreased significantly to 12.7±4.5 mmHg at 1 st week, and 12.8±3.7 mmHg at 1 st month (p<0.001, both). In 249 (30.7%) eyes, high IOP was detected on the first day. In 114 (45.8%) of these eyes, IOP was reduced by anterior chamber decompression while in 73 (29.3%) eyes glaucoma medication was prescribed. At first month 13 (1.6%) eyes had high IOP. C Co on nc cl lu us si io on n: : Although, a rise in IOP remains a problem in the postoperative first day; both anterior chamber decompression and glaucoma medication seem to be effective and safe to overcome thiscondition. In short term, uneventful phacoemulsification and intraocular lens implantation results in a decrease in IOP.K Ke ey y W Wo or rd ds s: : Phacoemulsification; intraocular pressure; glaucoma Ö ÖZ ZE ET T A Am ma aç ç: : Fakoemülsifikasyonun göz içi basıncı (GİB) üzerindeki etkisinin ve cerrahi sonrası yüksek GİB olgularına yaklaşımın değerlendirilmesi. G Ge er re eç ç v ve e Y Yö ön nt te em ml le er r: : Başkent Üniversitesi Adana Araştırma ve Uygulama Merkezi'nde komplikasyonsuz fakoemülsifikasyon cerrahisi geçiren 584 (330 erkek, 254 kadın) hastanın 812 gözüne ait veriler retrospektif olarak incelendi. Hastaların yaşları 26 ile 89 (65,5±9,8) arasında değişmekteydi. Ameliyat öncesi ve ameliyat sonrası 1. gün, 1. hafta ve 1. ay vizitlerindeki GİB değerleri kaydedildi. Yirmi iki üzerindeki değerler yüksek GİB olarak kabul edildi. Ameliyat sonrasında yüksek GİB değerlerini düşürmek için ön kamaradan boşaltma veya antiglokomatöz ilaç kullanımı tercih edildi. Göz içi basıncındaki değişimleri karşılaştırmak için ANOVA kullanıldı. B Bu ul lg gu ul la ar r: : Ameliyat öncesi ortalama GİB değeri 15,6±4,3 mmHg bulundu ve ameliyat sonrası 1. günde 19,7±9,0 mmHg'ya yükseldi (p<0,001). Göz içi basıncı, ameliyat sonrası 1. haftada 12,7±4,5 mmHg ve 1. ayda 12,8±3,7 mmHg olarak bulundu (her ikisi için de p<0,001). Ameliyat sonrası 1. günde 249 (%30,7) olguda yüksek GİB ölçüldü. Bu olguların 114'ünde (%45,8) GİB, ön kamaradan boşaltma yoluyla düşürülürken, 73 (%29,3) olguya antiglokomatöz ilaç reçete edildi. Birinci ayda 13 (%1,6) olguda yüksek GİB tespit edildi. S So on nu uç ç: : Ameliyat sonrası 1. günde göz içi basıncında tespit edilen yükselme sık görülen bir sorun olmakla beraber, hem ön kamaradan boşaltma, hem de antiglokomatöz ilaç kullanımı bu durumun üstesinden gelmek için etkin ve güvenli yöntemlerdir. Komplikasyonsuz fakoemülsifikasyon, ameliyat sonrasında kısa vadede GİB'de azalma sağlar.
Objectives: Autologous dermis fat graft (DFG) is being used in both primary and secondary socket surgeries. In the present study, we aimed to evaluate patients' satisfaction and possible intra-and postoperative complications in patients who had DFG transplantation. Ma te ri als and Met hods:In this retrospective study, the results of 17 patients who were operated between October 2008 and October 2012 were evaluated. Of these cases, 7 had primary and 10 had secondary DFG. Patient satisfaction was evaluated by asking the patients to fill out a questionnaire graded from 1 (not satisfied) to 4 (very satisfied). Additionally, the incidence of complications and requirement for another operation was noted. Re sults: The average patient age was 30.5±17.9 years. Patients with primary grafts were 100% satisfied with the outcome and could wear their prosthesis without any discomfort. In this group, one patient had delay in epithelialisation of the graft and ptosis, which was treated with frontal sling surgery and artificial tears. In patients with secondary grafts, 6 patients (60%) were satisfied with the outcome. Four patients were not satisfied from the result. One had inferior lid laxity; however, after lateral tarsal strip surgery, she could wear her prosthesis. Another patient developed inferior forniceal adhesion. He was treated with mucous membrane grafting and artificial tears and could wear his prosthesis. One patient had infection and contraction of the socket due to inappropriate postoperative medication use. Following repeated DFG transplantation, he was able to wear his prosthesis. Another patient had fat atrophy prior to secondary DFG transplantation and developed atrophy of the graft following surgery. Her family refused additional surgery. This patient could not wear any prosthesis. Conclusion: According to our results, we believe that DFG transplantation is successful in primary implantation. In secondary cases, correct patient selection is important to achieve good outcome. (Turk J Ophthalmol 2015; 45: 65-70) Key Words: Dermis-fat graft, patient satisfaction, socket surgery Amaç: Otolog dermis-yağ grefti (DYG) primer ve sekonder soket cerrahilerinde kullanılmaktadır. Biz bu çalışmamızda DYG implantasyonu geçirmiş olguları, hasta memnuniyeti ve cerrahi sırası ve sonrasındaki komplikasyonlar açısından değerlendirmeyi amaçladık. Ge reç ve Yön tem: Retrospektif planlanan çalışmamızda Ekim 2008 ile Ekim 2012 arasında opere olan 17 olgu incelendi. Bunlardan 7 olguya primer, 10 olguya sekonder DYG implante edilmişti. Hastaların memnuniyeti bir sorgulama formunda derecesi 1 (memnuniyetsiz) ile 4 (çok memnun) arasında bir değeri seçmesi istenerek değerlendirildi. Ayrıca komplikasyonlar, sıklıkları ve farklı bir cerrahi ihtiyaçları not edildi. Bulgular: Olguların yaş ortalaması 30,5±17,9 yıl idi. Primer DYG implante edilmiş olguların memnuniyeti %100 düzeyindeydi ve protezlerini bir rahatsızlık olmadan kullanıyorlardı. Bu grupta sadece bir hastada epitelizasyonda gecikme ve pitozis gelişmişti ve tedavisinde için fr...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.