The Arap and Melez Rivers discharge to Izmir Bay bringing wastewater together with rainwater coming from their catchment areas. There is an artificial harbor built at the discharge point of the Melez River acting as a sedimentation area for the suspended matter carried by these rivers. This area has a storage capacity of 3 to 4 years. After this period, the sediments are dredged and disposed from the region. In this study, various studies were carried out in order to determine the geotechnical properties and pollution parameters of the sediments; the results of many previous studies are also given. In the analyses done on dredging samples, it was observed that sulfur, oil and grease, phosphorus, nitrogen and heavy metal concentrations were very high. The reason for these high concentrations is the direct discharge of untreated wastewater formed in the industries located along the Arap and Melez Rivers. The pollutants carried to Izmir Bay by these rivers then settle down inside the artificial harbor and reach high concentrations in bottom sediments. As a result of this study, some possible environmental effects of land disposal of this material are discussed and suggestions are given for final disposal alternatives.
In dynamic pressure measurement phenomena, dynamic pressure calibration of the measurement chain including a pressure sensor, signal conditioning amplifier and data acquisition part is required. A drop mass dynamic calibration machine which is used for the dynamic calibration in hydraulic media was designed and developed. This study presents a research study and measurement results on the dynamic calibration of pressure transducers by using the newly developed machine.
This report gives the results of a comparison of pressure standards of three National Metrology institutes in the range of 0.7 MPa to 7 MPa. This comparison was piloted by UME and was carried out from February 2017 to March 2019. This work is a part of the GULFMET project and is registered as a supplementary comparison GULFMET.M.P-S1. The transfer standard used was a digital pressure gauge, model 745-1K, serial number 114944, manufactured by Paroscientific Inc, with a resolution of 1 hPa. The reference values have been determined from the weighted mean of the deviations which is a measurement error of the test instrument reported by the participants for each specified pressure.
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.