Dengue fever, a mosquito-borne disease commonly found in the tropics, is one of the most prevalent forms of Flavivirus infection in humans. Symptomatically, it is characterized by fever, arthralgia, headache, and rash. Ophthalmic manifestations can involve both the anterior and posterior segment. Panophthalmitis is rare in dengue hemorrhagic fever, and there is no report of culture-positive panophthalmitis in this setting. Here, we report a case of a serology-positive 33-year-old male patient of dengue hemorrhagic fever who developed sudden onset pain, redness, and proptosis in the right eye. The patient subsequently developed panophthalmitis in his right eye, and Bacillus cereus was isolated from eviscerated sample. This case provides unique insights into pathogenesis of panophthalmitis in dengue and highlights the management options.
Purpose: To evaluate the safety and efficacy of ultrasound cycloplasty in eyes with primary or secondary open-angle glaucoma, not amenable to adequate control of intra-ocular pressure (IOP) with medical treatment. Methods: Prospective interventional cohort study of 28 eyes of 28 subjects in a tertiary eye care centre in India in patients with open-angle glaucoma. All enrolled eyes underwent ultrasound cycloplasty with the second-generation probe with six shots of 8 s each, operated by a single surgeon between November 2018 and January 2020. They were followed up for a period of 12 months. The primary treatment outcome was IOP and the secondary outcomes were vision and postoperative complications. Results: A total of 28 eyes of 28 patients were studied, and the mean age was 63.82 ± 6.46 years. Primary open-angle glaucoma (75%) was the most common etiology. There was significant reduction in IOP from the baseline (24.93 ± 4.27 mmHg) to the postoperative value (15.82 ± 3.14 mmHg) at the end of 12 months ( P < 0.00001). Mean reduction in IOP was 9.14 ± 4.09 mmHg at 12 months (36.66%). Number of ocular hypotensives reduced significantly from baseline (3.32 ± 0.47) to 12-month postoperative follow-up (0.68 ± 0.74) ( P < 0.00001). Qualified success was achieved in 89.28% eyes. No major complications were noted. Conclusion: Ultrasound cycloplasty is found to be effective and safe in eyes with open-angle glaucoma because of the primary or secondary etiology, being more effective in the former.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.