A rapid, sensitive, and specific method was developed for determining perchlorate anion in lettuce, cantaloupe, bottled water, and milk. A test portion of chopped crop homogenate was extracted with diluted nitric acid and filtered. Milk proteins were precipitated with acetonitrile, and the supernatant, after centrifugation, was cleaned up on a graphitized carbon solid-phase extraction column. Water samples were analyzed directly. All test solutions were syringe filtered and mixed with an 18O4-labeled perchlorate internal standard before ion chromatography-tandem mass spectrometry. A strong anion exchange column eluted with 100 mM ammonium acetate in 50:50 (v/v) acetonitrile/water was interfaced via electrospray ionization to a triple stage quadrupole mass spectrometer operated in the negative ion mode. The labeled internal standard corrected for any sample matrix effects on measured signals. Four parent-to-product ion transitions, for loss of oxygen, were monitored for native and 18O4-labeled perchlorate anion, respectively: 35Cl-perchlorate, m/z 99 --> 83 and 107 --> 89; 37Cl-perchlorate, m/z 101 --> 85 and 109 --> 91. The limit of quantitation was 1.0 microg/kg in lettuce, 2.0 microg/kg in cantaloupe, 0.50 microg/L in bottled water, and 3.0 microg/L in milk. Native perchlorate was recovered from fortified test portions in the range 93-107% for lettuce, 107-114% for cantaloupe, 100-115% for bottled water, and 99-101% for milk.
An HPLC method with on-line cleanup coupled to the separation column is described for determination of (-)-norephedrine, (+)-norpseudoephedrine, (-)-ephedrine, (+)-pseudoephedrine, (-)-N-methylephedrine, (+)-N-methylpseudoephedrine, and (+/-)-synephrine in finished dietary supplement products. Test portions were extracted in acidified aqueous acetone. A filtered aliquot was cleaned up on a strong cation exchange (SCX) precolumn that later was automatically coupled to the SCX analytical column. Measurement was by full-scan UV spectra for confirmation of identity by spectral matching and real-time integration of three wavelength signals for multiple quantitation. (+/-)-Synephrine was also quantitated by native fluorescence. Recovery averaged 95-100%. Determination of the major ingredients (-)-ephedrine, (+)-pseudoephedrine, and (+/-)-synephrine compared favorably to findings by an independent LC-MS analysis for a set of 25 samples. The results of a survey were reported for total ephedrine alkaloid and synephrine content and were compared to content declaration, for approximately 48 finished products.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.