In this paper, a thermofluid model combining a lumped parameter heat transfer model and an air-flow model of a typical axial-field permanent-magnet (AFPM) machine is developed. The accuracy and consistency of the derived model are assessed by comparing the calculated flow rate and temperature values of a prototype machine with the measured ones. The developed thermofluid model is shown to perform thermal calculations with reasonable accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.