In the title compound, C4H11BrN+·Br−, both ions lie on crystallographic mirror planes. The C...Br distance is 1.943 (4) Å.
Key indicatorsSingle-crystal X-ray study T = 115 K Mean (F-B) = 0.003 Å R factor = 0.027 wR factor = 0.056 Data-to-parameter ratio = 19.2 For details of how these key indicators were automatically derived from the article, see
Materials and Methods Chemicals and reagentsABTS (2,2'-azino-bis (3-ethylbenzothiazoline-6-sufonic acid), potassium persulfate were purchased from Sigma-
vponiorrd ht i he I'mtnl Si»tr> (Htvprnmrnl. Nuthur ih> I'm led Statru nor tttr ( mted State* f.'nrrifv R^nearch and OrvrlopmrM AdminiHtralinn, nor an\ of ihrir *mp1ov^*». nor an\ of thpir con-(ru<'lors, siibtunlrBctorit. or (knr pmplnvNi. makn «n> warrantv. *»prnt* or implied, or mum'* *n\ lefai li»bilil\ or rMponnbilitv for thr arruract oompl*irnnit. or uwfulnM* of anx informuiion. apparaiui, product, or pruorieH diu-loKMl, or reprewnu Itiai m uir would not wtrtnff pnvatriy owned ih NOTICE This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Lnergy Research and Development Administration, nor any of their employees, nor any of their contractor*, subcontractors, or their employees, makes any warranty, impress or implied, o/ assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately owned rights. EVALUATION OF LITHIUM BCIRATF. AS ABSTRACTThe Harshaw Model 2271 TL Detector/Dosimeter system with lithium borate dosimeters was evaluated as a 7000-R dosimetry system. One hundred dosimeter cards having two dosimeters per card were irradiated up to ninety-eight times with x rays from a 250-keV (electron energy) GE x-ray machine.A twofold change in calibration was observed during the course of 98 irradiation cycles and a decrease in light output versus time lag between irradiation and reading was observed. The first card "failed" on the 36th cycle and only two cards survived to the 98th cycle. All of the failures were due to damage of the Teflon packaging, causing the dosimeters to hang up in the readout or to move in their card.This system could be used for screwworm fly dosimetry but is not considered ideal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.