Background: This prospective, randomised and blind study investigated the efficacy of laserpuncture for postoperative pain management in dogs. Method: Sixteen bitches were sedated with acepromazine and randomly treated before ovariohysterectomy with meloxicam 0.2 mg·kg−1 intramuscular or laserpuncture (wavelength 904 mm, frequency 124 Hz, potency 10 Joules, 100 s in each acupoint). Anaesthesia was performed with propofol, isoflurane/O2, and fentanyl. The Glasgow Composite Measure Pain Scale (GCMPS) and Dynamic Interactive Visual Analog Scale (DIVAS) were used to evaluate postoperative pain before and for 24 h after surgery. Morphine was administrated as rescue analgesia when pain scores were ≥3.33 (GCMPS). Differences between treatments, time points, and amount of rescue analgesia between groups were investigated by the Mann–Whitney test and the area under the curve (AUC) for GCMPS, Friedman, and Chi-squared tests, respectively (p < 0.05). Results: Dogs treated with laserpuncture presented lower GCMPS AUC for 24 h and lower GCMPS scores at 2 and 4 h postoperatively (p = 0.04). Three dogs treated with meloxicam required postoperatively rescue analgesia against none treated with laserpuncture. Conclusions: In this preliminary study, laserpuncture mitigated postoperative pain in dogs following ovariohysterectomy, and the technique is a promising adjunct to perioperative pain management in dogs undergoing soft tissue surgery.
This study aimed to evaluate reticulated hyaluronic acid alone or associated with ozone gas in the treatment of osteoarthritis due to hip dysplasia in dogs. Fourteen client-owned dogs were randomly assigned into two groups: Group 1-single intra-articular injection of hyaluronic acid; Group 2-single intra-articular infiltration injection of hyaluronic acid associated with ozone gas. Each hip joint received an average of 0.75 mL of reticulated hyaluronic acid ultrasound-guided. Ozone gas at a dose of 45 µg/mL was incorporated into hyaluronic acid by insufflation. Dogs were evaluated for body condition scoring, orthopedic examination and radiographic scores of the hip joints, goniometric measurements of the hip joints, visual gait score, and kinetic analysis. The evaluations were conducted immediately before treatments (M0), and at days 30 (M1), 60 (M2), and 90 (M3) after treatments. There were no significant differences in body mass and body condition scoring (5-point scale) in each group in all evaluation moments. The scores of orthopedic examination of the hip joints showed statistical differences in each group between moments (M0 > M3), but differences were not observed between groups. No statistical differences were found for radiographic scores in each group between moments, but differences were observed between groups immediately prior to treatments (G1 > G2) and 90 (G1 > G2) after treatments. Goniometric measurements of hip flexion and extension showed no significant differences in each group between moments or between groups. No statistical differences between groups were found concerning the lameness score. There were significant differences for lameness score among moments in Group 1, being M0 > M2 and M0 > M3, and Group 2 in which M0 > M1, M0 > M2, and M0 > M3. The mean percentage of change of PVF and VI between M3 and M0 in Group 1 was almost null and in Group 2 was positive, being 31.1 ± 29.4 and 10.6 ± 25.4, respectively. In conclusion, the intra-articular viscosupplementation alone or associated with ozone gas allowed improvement of lameness scores and orthopedic examination score. In Group 2 the association of ozone gas had better results on kinetic analysis.
This systematic review aimed to investigate the measurement properties of pain scoring instruments in farm animals. According to the PRISMA guidelines, a registered report protocol was previously published in this journal. Studies reporting the development and validation of acute and chronic pain scoring instruments based on behavioral and/or facial expressions of farm animals were searched. Data extraction and assessment were performed individually by two investigators using the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) guidelines. Nine categories were assessed: two for scale development (general design requirements and development, and content validity and comprehensibility) and seven for measurement properties (internal consistency, reliability, measurement error, criterion and construct validity, responsiveness and cross-cultural validity). The overall strength of evidence (high, moderate, low, or very low) of each instrument was scored based on methodological quality, number of studies and studies’ findings. Twenty instruments for three species (bovine, ovine and swine) were included. There was considerable variability concerning their development and measurement properties. Three behavior-based instruments scored high for strength of evidence: UCAPS (Unesp-Botucatu Unidimensional Composite Pain Scale for assessing postoperative pain in cattle), USAPS (Unesp-Botucatu Sheep Acute Composite Pain Scale) and UPAPS (Unesp-Botucatu Pig Composite Acute Pain Scale). Four instruments scored moderate for strength of evidence: MPSS (Multidimensional Pain Scoring System for bovine), SPFES (Sheep Pain Facial Expression Scale), LGS (Lamb Grimace Scale) and PGS-B (Piglet Grimace Scale-B). Most instruments (n = 13) scored low or very low for final overall evidence. Construct validity was the most reported measurement property followed by criterion validity and reliability. Instruments with reported validation are urgently required for pain assessment of buffalos, goats, camelids and avian species.
Pain assessment guides decision-making in pain management and improves animal welfare. We aimed to investigate the reliability and validity of the UNESP-Botucatu cattle pain scale (UCAPS) and the cow pain scale (CPS) for postoperative pain assessment in Bos taurus (Angus) and Bos indicus (Nelore) bulls after castration. Methods: Ten Nelore and nine Angus bulls were anaesthetised with xylazine–ketamine–diazepam–isoflurane–flunixin meglumine. Three-minute videos were recorded at -48 h, preoperative, after surgery, after rescue analgesia and at 24 h. Two evaluators assessed 95 randomised videos twice one month apart. Results: There were no significant differences in the pain scores between breeds. Intra and inter-rater reliability varied from good (>0.70) to very good (>0.81) for all scales. The criterion validity showed a strong correlation (0.76–0.78) between the numerical rating scale and VAS versus UCAPS and CPS, and between UCAPS and CPS (0.76). The UCAPS and CPS were responsive; all items and total scores increased after surgery. Both scales were specific (81–85%) and sensitive (82–87%). The cut-off point for rescue analgesia was >4 for UCAPS and >3 for CPS. Conclusions. The UCAPS and CPS are valid and reliable to assess postoperative pain in Bos taurus and Bos indicus bulls.
Society has been increasingly concerned about the impact of pain on farm animal welfare. This systematic review aims to provide evidence relating to the measurement properties (i.e. reliability, validity, and sensitivity) of pain scoring instruments used for pain assessment in farm animals. A literature search will be performed using five databases (MEDLINE, EMBASE, Web of Science, CAB abstracts and Biological Abstracts) and search terms related to pain, pain scales and different species of farm animals. Eligibility criteria will include full-text studies on the development and/or validation of acute and chronic pain scoring instruments for farm animals including bovine (beef and dairy), ovine, caprine, camel, swine and poultry. Exclusion criteria will include studies that report the use of pain scales for the validation of another instrument, or those reporting ethograms/list of behaviors potentially indicating pain without a scoring system. Study titles and their abstracts will be screened for eligibility by one investigator. Full-text articles will be independently reviewed for eligibility and evaluated by two investigators. Relevant information will be recorded and evaluated systematically according to the Consensus‐based Standards for the Selection of Health Measurement Instruments (COSMIN) checklist using an adapted data collection sheet. The following measurement properties and characteristics of the instruments will be assessed: content validity (internal consistency, structural and cross-cultural validity), reliability, measurement error, criterion and construct validity, responsiveness, interpretability and feasibility. Following the assessment of methodological quality and quality of the findings, evidence for each measurement property will be summarized into high, moderate, low or very low. This systematic review will provide further insights into the evidence-based measurement properties of pain scoring instruments in farm animals. It may identify possible gaps of knowledge with these tools as a potential target for future studies in farm animals with a positive impact on animal welfare.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.