A new method of analysis of vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde in brandy and wine by high-performance capillary electrophoresis is described. Electrophoretic mobility of these compounds is achieved by a borate buffer at pH 9.3. At this pH, the sensitivity of UV detection of these phenolic aldehydes also increases. UV absorptions at 348, 362, 404, and 422 nm were selected for monitoring vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde, respectively. This procedure was performed simultaneously during one run using a diode array detector. Samples of brandy or wine were analyzed directly without concentration, extraction, or any other preliminary treatment of the test sample. The limits of detection were found to be 0.275, 0.1425, 0.1475, and 0.1975 ppm for syringaldehyde, coniferaldehyde, sinapaldehyde, and vanillin, respectively, which is acceptable for analysis of both brandy and wine aged in oak barrels. The method has been shown to be linear in a range from 0.3 to 57 mg/L. Recoveries ranged between 99.9% and 107.7% for all of the compounds tested. Repeatability and reproducibility of the method were high. The relative standard deviation was consequently approximately 3% and also between 4.47% and 6.89% for all tested compounds. The method is useful for the identification of counterfeit brandy, which is easy to recognize by the absence of sinapaldehyde, syringaldehyde, and coniferaldehyde, which are not detectable in false brandy.
No abstract
No abstract
Mechanical methods of deployment of permanent, continuous analog visible recording of signals complicate the design of analog recorders and light–beam oscilloscopes with the continuous visible recording of low–frequency processes and periodic output of recording frames, reduce their reliability and accuracy, make it difficult to adjust deployment steps, increase power and dimensions, and also lead to additional geometrical and optical errors in light–beam oscilloscopes. To eliminate these shortcomings, electronic methods for deployment of continuous analog visible recording are proposed and analysed, on the basis of which corresponding devices are also developed, created, and tested, with the help of which the proposed electronic methods are tested and verified based on ASEO type Automatic seismic electrographic oscilloscopes.
One of the most pressing problems of modern astrophysics refers to the conclusions about the existence of dark matter and energy that have some uncertainties, which leads to much greater uncertainty in cosmological problems. This paper shows that if the absolute magnitudes of the Ia type supernovae change with time corresponding to the redshift z = 1 (i.e., the evolution of luminosities occurs) by only 0.3 magnitudes, then the required fraction of dark energy in the Universe becomes equal to 0, which contradicts the hypothesis of the existence of dark energy. The second contradiction in the dark energy existence hypothesis arises from the violation of the homogeneity of the Universe. For verification of this the studies on the possibility of violation of homogeneity have been carried out, and at least two domains of large Voids have been found by us, sizes of which reach up to one gigaparsec. Thus, the present work substantiates the existence of the above-mentioned circumstances, which make the hypothesis of the existence of dark energy highly doubtful./Ժամանակակից աստղաֆիզիկայի հիմնական խնդիրներից մեկը մութ զանգվածի և էներգիայի վերաբերյալ կատարված հետևությունների որոշ անորոշություններն են, ինչը հանգեցնում է ավելի մեծ անորոշությունների տիեզերագիտական խնդիրներում: Ներկայացվող աշխատանքում ցույց է տրված, որ եթե Ia տիպի գերնորերի բացարձակ մեծությունները z=1 կարմիր շեղմանը համապատասխանող ժամանակի ընթացքում փոխվում են ընդամենը 0.3 մեծությամբ (այսինքն կա աստղի պայծառության էվոլյուցիա), ապա տիեզերքում մութ էներգիայի պահանջվող չափաբաժինը դառնում է 0, ինչը հակասում է մութ էներգիայի գոյության վարկածին: Մութ էներգիայի գոյության վարկածի երկրորդ հակասությունը առաջանում է տիեզերքի համասեռության խախտման հետևանքով: Դրա ստուգման համար մեր կողմից կատարվել են համասեռության խախտման հնարավորության հետազոտություններ և հայտնաբերվել են մեծամասշտաբ դատարկությունների (Void) առնվազն երկու տիրույթ, որոնց չափերը հասնում են մինչև մեկ գիգապարսեկի։ Այսպիսով, ներկայացվող աշխատանքում հիմնավորվում է վերը նշված հանգամանքների առկայությունը, որը խիստ կասկածելի է դարձնում մութ էներգիայի գոյության վարկածը:
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.