Recebido em 1/12/09; aceito em 25/3/10; publicado na web em 29/6/10 A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C 18 (250 mm × 4.6 mm, 5 μm) Vertical ® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flowrate of 1.2 mL min -1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.
The present study reports the solid-state properties of Fluvastatin sodium salt crystallized from different solvents for comparison with crystalline forms of the commercially available raw material and United States Pharmacopeia (USP) reference standard. Fluvastatin (FLV) samples were characterized by several techniques; such as X-ray powder diffractometry, differential scanning calorimetry, thermogravimetry, liquid and solid-state nuclear magnetic resonance spectroscopy, diffuse reflectance infrared Fourier transform spectroscopy, and scanning electron microscopy. In addition, intrinsic dissolution rate (IDR) of samples was performed in order to study the influence of crystalline form and other factors on rate and extent of dissolution. Three different forms were found. The commercial raw material and Fluvastatin-Acetonitrile (ACN) were identified as "form I" hydrate, the USP reference standard as "form II" hydrate and an ethanol solvate which presented a mixture of phases. Form I, with water content of 4%, was identified as monohydrate.
A stability-indicating reversed-phase high-performance liquid chromatography method is developed and validated for the determination of venlafaxine hydrochloride (VEN) in extended-release capsules containing spherical beads and for dissolution studies. The method is carried out on a Luna C(18) column (250 mm x 4.6 mm) maintained at 35 degrees C. The mobile phase is composed of ammonium-acetate buffer 32 mM, adjusted to pH 6.8 with phosphoric acid-acetonitrile-methanol (62:30:8, v/v/v), run at a flow rate of 1.0 mL/min, and detection at 226 nm. Validation parameters such as the specificity, linearity, precision, accuracy, and robustness are evaluated, giving results within the acceptable range. In order to evaluate the best dissolution condition, the dissolution profiles are performed under different conditions, such as media (HCl, water, phosphate buffer), apparatus (I and II), and dissolution rates (50, 75, and 100 rpm). The kinetics release mechanism is evaluated by fitting different models, such as the zero order rate, first order, and Higuchi. Moreover, the proposed method is successfully applied for the assay of VEN in extended-release capsules.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.