We previously proposed that, during the infusion of either labeled leucine or its alpha-ketoacid, alpha-ketoisocaproate (KIC), the plasma specific activity (SA) of the transaminated product of the infused tracer ("reciprocal pool SA") may better reflect the intracellular leucine SA than the plasma SA of either infused tracer ("primary pool SA"). To test this hypothesis, 14 dogs were simultaneously infused intravenously with [3H]leucine and [14C]KIC, and blood and tissue compartments were sampled. The ratios of [3H]-leucine to [14C]leucine [( 3H]/[14C]leucine) in mixed tissue proteins and in the intracellular space of striated muscle were the same as the ratio of the isotope infusion rates and similar, although slightly lower (P less than 0.01), than [3H]KIC/[14C]leucine SA (ratio of reciprocal pool SA) in plasma. Plasma [3H]KIC/[14C]leucine SA were essentially identical to the [3H]/[14C] of leucine in 1) mixed liver proteins, 2) intrahepatic free leucine, and 3) fibrin. The [3H]/[14C]leucine in mixed renal proteins and in the intracellular space of kidney and erythrocytes were similar to those of the venous plasma [3H]/[14C]leucine SA. The plasma [3H]KIC and [14C]leucine SA (the reciprocal pool SA) were similar to the SA of [3H]- and [14C]leucine in the intracellular space of all organs investigated with the exception of kidney. Therefore, in postabsorptive dogs, the plasma SA of the transaminated product of the infused labeled KIC or leucine is an excellent predictor of the intracellular leucine SA in all tissues investigated with the exception of kidney.
The three-dimensional coordinates of points in the ribs of two supine relaxed males, holding their breath at functional residual capacity (FRC) and with their glottis closed at total lung capacity (TLC), were obtained from volumetric X-ray computed tomographical images. The orientation of planes that best fit the data for each rib at each lung volume and the circular arcs that fit the points in the planes of the ribs were determined, and average values of these geometrical parameters for ribs 3-7 are reported. The planes of the ribs at TLC can be described as displaced from the planes at FRC by a rotation about an axis that passes near the spine. The pump handle and bucket handle components of rotation are 11 and 13 degrees, respectively, for rib 3 and both decrease with increasing rib number to 7 and 10 degrees at rib 7. The angles between the axes of rotation and the midplane are approximately 35 degrees for all 5 ribs. The radii of the circular arcs fit to the data at TLC are slightly larger than those at FRC, and this suggests that there is a small component of rotation normal to the plane of the rib.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.