Effects of velocity gradient (G value) and mixing time (t) on the coagulation of particles were investigated by monitoring particle counts in a rapid mixing process. Total particle counts after mixing of 30 s at G value of 200 s(-1) were similar to the summation of clay particles and alum precipitates at alum dose of 30 mg L(-1). Although small particles (microflocs less than 5 microm) were formed within the mixing time of 30 s, macroflocs larger than 8 microm did not increase significantly until the mixing time of 60 s. However, macroflocs larger than 8 microm started to increase after mixing of 75 s and they reached the maximum counts at 150 s. On the other hand, macroflocs larger than 8 microm decreased after mixing time of 180 s due in breaks of the macroflocs, which resulted in resuspension of small particles. The rapid mixing conditions for the maximum growth of macroflocs were the G value of 200 s(-1) and the mixing time of 150 s, which confirmed the best performance of turbidity removal in jar tests. Growth and break of particles and flocs in a rapid mixing step would influence significantly on the sequential flocculation and sedimentation processes for turbidity removal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.