The design of a 6.5-MV linear transformer driver (LTD) for flash-radiography experiments is presented. The design is based on a previously tested 1-MV LTD and is predicted to be capable of producing diode voltages of 6.5 MV for a 50-Ω radiographic-diode load. Several fault modes are identified, and circuit simulations are used to determine their effect on the output pulse and other components. For all the identified fault modes, the peak load voltage is reduced by less than 5%.Index Terms-Circuit simulation, electron accelerator, pulse power systems, radiography, X-ray applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.