Background: Imaging of the portal vein prior to puncture for TIPS is essential. Purpose: With this study, we examined a modified retrograde portography with regard to the reliable representation of the portal vein. Material and Methods: Prospective evaluation of 65 TIPS interventions with regard to the delimitation of the portal vein and the exact parameters of retrograde portography such as catheter diameter and contrast medium volume per injection. Results: Retrograde portographies with a large-lumen catheter (10 F) and a large contrast medium volume (40 mL) were performed in 35/63 patients with significantly better delineation of the portal vein than when using 5 F catheters with 10 mL contrast medium. Conclusion: The so-called high volume retrograde portography leads to better delimitation of the portal vein during TIPS application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.