Antibacterial copper−hydroxyapatite (Cu−HA) composite coatings on titanium were synthesized using a novel process consisting of two consecutive electrochemical reactions. In the first stage, HA nanocrystals were grown on titanium using the cathodic electrolytic synthesis. The HAcoated titanium was then used as the cathode in a second reaction stage to electrochemically reduce Cu 2+ ions in solution to metallic Cu nanoparticles. Reaction conditions were found that result in nanoscale Cu particles growing on the surface of the HA crystals. The two-stage synthesis allows facile control of copper content in the HA coatings. Antibacterial activity was measured by culturing Escherichia coli (Gram-negative) and Staphylococcus aureus (Gram-positive) in the presence of coatings having varying copper contents. The coatings displayed copper concentration-dependent antibacterial activity against both types of bacteria, likely due to the slow release of copper ions from the coatings. The observation of antibacterial activity from a relatively low loading of copper on the bioactive HA support suggests that multifunctional implant coatings can be developed to supplement or supplant prophylactic antibiotics used in implant surgery that are responsible for creating resistant bacteria strains.
Ventilation is of primary concern for maintaining healthy indoor air quality and reducing the spread of airborne infectious disease, including COVID-19. In addition to building-level guidelines, increased attention is being placed on room-level ventilation. However, for many universities and schools, ventilation data on a room-by-room basis are not available for classrooms and other key spaces. We present an overview of approaches for measuring ventilation along with their advantages and disadvantages. We also present data from recent case studies for a variety of institutions across the United States, with various building ages, types, locations, and climates, highlighting their commonalities and differences, and examples of the use of this data to support decision making.
The COVID-19 pandemic increased the demand for indoor air cleaners. While some commercial electronic air cleaners can be effective in reducing primary pollutants and inactivating bioaerosol, studies on the formation of secondary products from oxidation chemistry during their use are limited. Here, we measured oxygenated volatile organic compounds (OVOCs) and the chemical composition of particles generated from a hydroxyl radical generator in an office. During operation, enhancements in OVOCs, especially low-molecular-weight organic acids, were detected. Rapid increases in particle number and mass concentrations were observed, corresponding to the formation of highly oxidized secondary organic aerosol (SOA) (O:C ∼ 1.3), with an enhanced signal at m / z 44 (CO 2 + ) in the organic mass spectra. These results suggest that organic acids generated during VOC oxidation contributed to particle nucleation and SOA formation. Nitrate, sulfate, and chloride also increased during the oxidation without a corresponding increase in ammonium, suggesting organic nitrate, organic sulfate, and organic chloride formation. As secondary species are reported to have detrimental health effects, further studies should not be limited to the inactivation of bioaerosol or reduction of particular VOCs, but should also evaluate potential OVOCs and SOA formation from electronic air cleaners in different indoor environments.
Airborne virus transmission during the COVID-19 pandemic increased the demand for indoor air cleaners. While some commercial electronic air cleaners could be effective in reducing primary pollutants and inactivating bioaerosol, studies on the formation of secondary products from oxidation chemistry during their use are limited. Here, we measured oxygenated volatile organic compounds (OVOCs) and the chemical composition of particles generated from a hydroxyl radical generator in an office. During operation, enhancements in OVOCs, especially low-molecular-weight organic and inorganic acids, were detected. Rapid increases in particle number and volume concentrations were observed, corresponding to the formation of highly-oxidized secondary organic aerosol (SOA) (O:C ~1.3). The organic mass spectra showed an enhanced signal at m/z 44 (CO2+) and the aerosol evolved with a slope of ~ -1 in the Van Krevelen diagram. These results suggest that organic acids generated during VOC oxidation contributed to particle nucleation and SOA formation. Nitrate, sulfate, and chloride also increased during the oxidation without a corresponding increase in ammonium, suggesting organic nitrate, organic sulfate, and organic chloride formation. As secondary species are reported to have detrimental health effects, further studies are needed to evaluate potential OVOCs and SOA formation from electronic air cleaners in different indoor environments.
Ventilation is of primary concern for maintaining healthy indoor air quality and reducing the spread of airborne infectious disease, including COVID-19. In addition to building-level guidelines, increased attention is being placed on room-level ventilation. However, for many universities and schools, ventilation data on a room-by-room basis are not available for classrooms and other key spaces. We present an overview of approaches for measuring ventilation along with their advantages and disadvantages. We also present data from recent case studies for a variety of institutions across the United States, with various building ages, types, locations, and climates, highlighting their commonalities and differences, and examples of the use of this data to support decision making.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.