Background-Long term effects of left ventricle (LV) repair surgery (LVR) for ischemic cardiomyopathy are not well understood. Methods and Results-Sixty-nine rats developed ischemic cardiomyopathy with large akinetic LV area 4 weeks after the left anterior descending artery was ligated. In a second surgery 4 weeks later, 33 rats underwent LVR by plication of the akinetic LV area (LVR group), and 36 underwent rethoracotomy alone (sham group). No medication was used in either group. All rats survived the second surgery. LV end-diastolic dimension as measured by echocardiography, LV fractional shortening, and the maximal end-systolic pressure-volume relationship (E max ) as calculated from the data by catheter-tipped manometer and echocardiography improved in the LVR group after the second surgery, but LV end-diastolic dimension and E max gradually deteriorated as time passed. LV end-diastolic pressure improved 1 week after LVR but rose significantly 4 weeks after LVR. Brain natriuretic peptide mRNA was lower in the LVR group than in the sham group 1 week after LVR but not 4 weeks postoperatively.
Conclusions-Initial
This model enables reproducible physiological evaluation of the LV after VRS, and since the rats show postoperative survival, it provides a useful tool for various investigations.
We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using sheep. The flow rates ranged from 2.5-5.5 L/min. The sheep that lived the longest (46 days) died of an embolism as a result of the thrombus in the pump. No thrombus formation was observed in other pumps. Plasma free hemoglobin levels ranged from 9 to 18 mg/dl, which led to the conclusion that the hemolysis level remained within an acceptable range. Two driving modes were compared. The slope of the pressure-flow relationship plot under a constant motor current mode was steeper than that under a constant rotational speed mode, and thus, the flow fluctuation decreased. In conclusion, the MSCP is durable for more than a month at the current stage of development and is a promising device for long-term ventricular assist.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.