Glomus tumors are a rare, benign neoplasm and 75% exist in the subungual region. Extradigital glomus tumors are much more difficult to diagnose because of their atypical location and symptoms. Furthermore, if their symptoms are similar to neuropathic pain, the patient can suffer from misdirected treatment due to misdiagnosis. It is essential to perform careful evaluation of the lesion itself in order to reduce misdiagnosis. Ultrasonography is a useful, non-invasive method that can be easily performed in the pain clinic for local evaluation and diagnosis. We report a case of misdiagnosed glomus tumor in the thigh which was properly diagnosed after ultrasonography.
Central venous catheterization (CVC) can be difficult, especially with pediatric patients in critical care. Accessing the subclavian vein (SCV) can cause serious complications, including pneumothorax, arterial puncture, and hemothorax. Recently, the ultrasonographic (USG) technique has gained popularity, but its efficiency is not yet confirmed. Subclavian venous catheterization (SCVC) through the supraclavicular approach (SCA) with USG or accessing the brachiocephalic vein through the infraclavicular approach (ICA) has been reported in the past. A useful technique is reported that involves the use of a 40 mm probe rather than the usual 25 mm probe in order to confirm the location of the needle while successfully performing subclavian venous catheterization in pediatric patients weighing 1.1 kg to 15.0 kg.
BackgroundPrevious studies have shown that if performed without radiographic guidance, the loss of resistance (LOR) technique can result in inaccurate needle placement in up to 30% of lumbar epidural blocks. To date, no study has shown the efficacy of measuring the depth of the posterior complex (ligamentum flavum, epidural space, and posterior dura) ultrasonographically to distinguish true and false LOR.Methods40 cervical epidural blocks were performed using the LOR technique and confirmed by epidurograms. Transverse ultrasound images of the C6/7 area were taken before each cervical epidural block, and the distances from the skin to the posterior complex, transverse process, and supraspinous ligament were measured on each ultrasound view. The number of LOR attempts was counted, and the depth of each LOR was measured with a standard ruler. Correlation of false and true positive LOR depth with ultrasonographically measured depth was also statistically analyzed.Results76.5% of all cases (26 out of 34) showed false positive LOR. Concordance correlation coefficients between the measured distances on ultrasound (skin to ligamentum flavum) and actual needle depth were 0.8285 on true LOR. Depth of the true positive LOR correlated with height and weight, with a mean of 5.64 ± 1.06 cm, while the mean depth of the false positive LOR was 4.08 ± 1.00 cm.ConclusionsUltrasonographic measurement of the ligamentum flavum depth (or posterior complex) preceding cervical epidural block is beneficial in excluding false LOR and increasing success rates of cervical epidural blocks.
BackgroundTo analyze how lidocaine 40 mg mixed prevents injection pain of propofol affects the onset time of rocuronium, tracheal intubating conditions and intubation related hemodynamic changes.MethodsThis study consisted of 70 patients with an American Society of Anesthesiologists (ASA) physical status class 1 or 2 for general anesthesia. All the patients were randomly allocated into two groups: propofol 2 mg/kg plus normal saline 2 ml (Group C) and propofol 2 mg/kg plus 2% lidocaine 40 mg (Group L). Each group was administrated intravenously during induction and the patient was intubated 1 minute after an injection of 0.6 mg/kg of rocuronium. The time at disappearance of the first twitch and intubation scores were recorded. Also, blood pressure and heart rate were measured at the baseline, after intravenous injection of propofol, before intubation, and at 0, 1, 2, 3 and 5 minutes after intubation.ResultsThere were no significant differences between group C and L (P > 0.05).Conclusions40 mg of lidocaine mixed with propofol to prevent injection pain did not affect the onset time of rocuronium, intubating conditions and intubation related hemodynamic changes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.