A simple method is presented for the simultaneous determination of morphine, 6-acetylmorphine, codeine, cocaine, benzoylecgonine, cocaethylene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) in vitreous humor by high-performance liquid chromatography with photodiode array detector after solid-phase extraction with Oasis® HLB cartridges and dichloromethane as eluent. The chromatographic process was carried out using an XTerra® RP8 column (250 × 4.6 mm i.d., 5 µm particle size) and a mobile phase composed of acetonitrile and pH 6.5 phosphate buffer in gradient mode. A linear response from the detector was obtained within the concentration range of 0.1-4 µg ml(-1) , with correlation coefficients higher than 0.99. The limits of detection were lower than 30 ng ml(-1) for all the drugs studied, the coefficients of variation fluctuated between 0.1 and 12.4%, and the average recoveries were higher than 78% for all the drugs except for EDDP, with a value of 66.4%. Finally, the proposed method was applied to 15 vitreous humor samples coming from individuals who had died from opiate and/or cocaine overdose, showing consumption of cocaine in 14 cases, methadone in five cases and heroin in three cases. Average concentrations of 0.30 µg ml(-1) for morphine, 0.24 µg ml(-1) for 6-acetylmorphine, 0.10 µg ml(-1) for codeine, 0.81 µg ml(-1) for cocaine, 1.26 µg ml(-1) for benzoylecgonine, 0.15 µg ml(-1) for cocaethylene, 0.11 µg ml(-1) for methadone and 0.68 µg ml(-1) for EDDP were obtained.
Robust and simple validated analytical methods are required in postmortem toxicology to confirm immunoassay screening analysis of drugs of abuse. In this work, microwave-assisted extraction (MAE) was evaluated as an alternative method for extraction of target compounds such as cocaine, benzoylecgonine, cocaethylene, morphine, codeine, 6-monoacetylmorphine, methadone, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from vitreous humor. The MAE procedure parameters, namely, extraction temperature, time, and solvent volume, were optimized using a central composite design and applying desirability functions. The optimal conditions for extraction were 80 °C, 8 min, and 15 mL of dichloromethane solvent. The MAE-high-performance liquid chromatography-diode-array detection method was validated, showing its capability for the detection of concentrations in the range from 33 to 76 ng mL(-1) and recoveries in the range from 87 to 99.3% for all drugs. The MAE-based method was tested for 15 vitreous humor samples from forensic cases and its performance was compared with that of a solid-phase extraction method previously developed by our group. In general, better recovery and precision were achieved with the use of the MAE-based procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.