Rabeprazole has a comparable efficacy compared to ranitidine when given on-demand for the treatment of NERD. Both medications were associated with improved quality of life.
This paper presents a wireless cardiopulmonary activity measurement system. This system generates a continuous wave toward a person's chest set at a distance of 1 m, then reflected to the system. Using a vector network analyzer, the phase of S21 is computed. The phase variation of S21 contains information about cardiopulmonary activity. Several processing techniques are used to separate heartbeat signal from cardiorespiratory signal either in frequency or in temporal domain. The measurements were performed simultaneously with a PC-based electrocardiogram to validate the heartbeat rate detection techniques. In conclusion, processing techniques used in this paper give accurate results.
This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S 21. The phase variation of S 21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PCbased electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.
Abstract-This paper presents a wireless measurement system for cardiopulmonary activity. This system generates a continuous wave signal at 2.4 GHz toward the target and then measures the reflected signal. The target is the person's chest set at a distance of 1 m. The radar system contains a vector network analyzer, which measures the phase of S 21 . The phase variation of S 21 contains information about heart and respiration activity. Measurements are performed with two different conditions, while the person is holding respiration for 10 seconds and then breathing normally for the same duration. Filtering is used as processing technique to separate heartbeat signal from respiratory signal in the second case. The measurements were performed simultaneously with a PC-based electrocardiograph which is used as a reference to validate the information extracted from the measured signals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.