DW images provided useful information for evaluating the T stage of bladder cancer, particularly in differentiating T1 or lower tumors from T2 or higher tumors. The ADC may in part predict the histologic grade of bladder cancer.
Targeting self-renewal is an important goal in cancer therapy and recent studies have focused on Notch signalling in the maintenance of stemness of glioma stem cells (GSCs). Understanding cancer-specific Notch regulation would improve specificity of targeting this pathway. In this study, we find that Notch1 activation in GSCs specifically induces expression of the lncRNA, TUG1. TUG1 coordinately promotes self-renewal by sponging miR-145 in the cytoplasm and recruiting polycomb to repress differentiation genes by locus-specific methylation of histone H3K27 via YY1-binding activity in the nucleus. Furthermore, intravenous treatment with antisense oligonucleotides targeting TUG1 coupled with a drug delivery system induces GSC differentiation and efficiently represses GSC growth in vivo. Our results highlight the importance of the Notch-lncRNA axis in regulating self-renewal of glioma cells and provide a strong rationale for targeting TUG1 as a specific and potent therapeutic approach to eliminate the GSC population.
The OPERA neutrino experiment at the underground Gran Sasso Laboratory has measured the velocity of neutrinos from the CERN CNGS beam over a baseline of about 730 km. The measurement is based on data taken by OPERA in the years 2009, 2010 and 2011. Dedicated upgrades of the CNGS timing system and of the OPERA detector, as well as a high precision geodesy campaign for the measurement of the neutrino baseline, allowed reaching comparable systematic and statistical accuracies.An arrival time of CNGS muon neutrinos with respect to the one computed assuming the speed of light in vacuum of (6.5 ± 7.4 (stat.) +8.3 −8.0 (sys.)) ns was measured corresponding to a relative difference of the muon neutrino velocity with respect to the speed of light (v − c)/c = (2.7 ± 3.1 (stat.) +3.4 −3.3 (sys.)) × 10 −6 . The above result, obtained by comparing the time distributions of neutrino interactions and of protons hitting the CNGS target in 10.5 µs long extractions, was confirmed by a test performed at the end of 2011 using a short bunch beam allowing to measure the neutrino time of flight at the single interaction level.
Image quality and localization improved significantly with ERC imaging compared with BAC imaging. For experienced radiologists, the staging performance was significantly better with ERC imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.