The Savonius turbine, although simple in construction, typically has a maximum power coefficient (cP) of about 0.2. This is significantly lower than the cP of the axial flow propeller-type turbine which typically can be as high as 0.5. However, a simple means to improve the cP of a Savonius turbine is to install it above a forward facing step, for example, a cliff or a building. In this work, prior experimental results of the tow testing of a Savonius turbine installed above a finite-width bluff body were used to validate computational fluid dynamics simulation of the same experimental conditions. The validated simulation settings were then used to obtain the maximum cP of a similar turbine of finite width but installed above an infinite-width forward facing step over a range of installation positions above and behind the step.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.