Using Photon-Density-Waves (PWD), (multiple) objects embedded in a highly scattering medium with optical properties similar to tissue are detected. The measurements were performed with near-infra-red laser light at 675 nm which was either kept continuous-wave (CW) or amplitude modulated (AM) at 219 MHz or 650MHz. We find that the spatial resolution of the projection image shows only slight improvements as the frequency is increased. This improvement comes at the expense of signal strength in the modulated part of the light. That is, the PWD shows a much stronger attenuation as compared to the CW light intensity. The implications of the lower signal-tonoise ratio at high modulation frequencies is that the modulated light projections are less suitable for further data processing. For a given data acquisition system, this fact cancels the advantages of the higher raw resolution of PWD as compared to CW light. Therefore, we find no clear advantage of PWD over CW light for obtaining sharper tomographic images of the diffuse media, regardless of the inverse scattering method used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.