BackgroundNasal septal perforation (NSP) may alter nasal airflow patterns and physiology. To the best of our knowledge, no studies in the English literature have investigated the effect of NSP and its treatment on polysomnographic parameters. In this study, we aimed to investigate polysomnographic parameters in patients with NSP as well as changes in those parameters after treatment of NSP.Material/MethodsNineteen patients diagnosed with NSP were included in the study. All patients had baseline and post-procedure polysomnographies (PSG) after insertion of silicone septal button for closure of NSP.ResultsBoth median AHI [5.30 (14.40) vs. 2.40 (14.50)] and median supine AHI [10.00 (42.10) vs. 6.60 (37.00)] decreased after correction of the perforation. There was a large reduction in median supine AHI in patients with a perforation size >66 mm2 [10.10 (34.15) vs. 1.60 (28.30)].ConclusionsWe conclude that NSP did not cause any deterioration in objective sleep parameters as determined by PSG, other than a decrease in REM sleep duration and an increase in supine AHI. Correction of NSP did not affect REM duration and supine AHI decreased after treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.