The effects of the initial storage temperature and the PA film packaging on the extension of the shelf-life and the improvement of the postharvest storage quality of muskmelons were studied during their storage. Their storage quality was tested as follows: PA-film-wrapped muskmelons, stored at 2℃ or 7℃ for 30 days after their harvest, were kept at 10℃ for 27 days (total: 57 days). On the fifth day of storage at 10℃ (35th day overall), the weight loss reached 6.4% in the 7-control. However, the 2-PA showed the smallest loss of 2.2%. The soluble solids content and the acidity that were measured before the storage were 10.8 °brix and 0.26% in all the groups. After 27 days of storage at 10℃ (on the 57th day overall), the values were highest in the 2-PA group with 9.7 °brix and 0.15%, respectively. Microorganisms were not detected at first; but on the fifth day of storage at 10℃ (35th day overall), their values were 3.87 and 2.68 log CFU/g in the seven-control and the 2-PA, respectively. In other words, the 2-PA was found to be more effective in inhibiting microbial proliferation. In relation to sensory properties such as appearance, flavor, sweetness and chewiness, the 2-PA was superior to the other groups and was found to be most effective in improving the storability of muskmelons. In conclusion, it was found that low-temperature injury and fast storage quality deterioration did not occur in film-wrapped muskmelons that were stored at 2℃ for 30 days after they were harvested.
Simultaneous determination of three corticosteroids (clobetasol propionate, betamethasone dipropionate, fluticasone propionate) in moisturizers was performed by using liquid chromatography (LC) coupled with tandem mass spectrometry (MS/ MS). Sample preparation was conducted by the liquid-liquid extraction (LLE). Moisturizers include emulsifying agent and it forms micelles. In order to improve the extraction efficiency of corticosteroids trapped in micelle, newly developed-optimized extraction conditions which can remove the matrix effect from moisturizers was applied with various pH conditions in LLE extraction stage of sample preparation. Thus, the addition of 10 µL of 1 M HCl into moisturizers sample before extraction could improve the extraction efficiency. For the quantitative analysis, SRM table that contained specific transition of all of target corticosteroids was created. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), limit of quantization (LOQ) and recovery. Over the 0.99 r 2 value was obtained in calibration standard range. Effective accuracy and precision were also obtained. LODs were below 31 ng/mL and LOQs were estimated below 94 ng/mL for all corticosteroids tested.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.