The specific of metrological support for different types of dosemeters are considered. Gamma-ray sensors are commonly used for measuring radiation doses as also the fluid levels in the industry. Typically, the 60 Co or 137 Cs isotopes as the radiation source are applied. For instance, in the USA, such detectors are beginning to be used as part of the Container Security Initiative [1]. Problems of their metrological assurance are becoming more general. They require the development of metrological support. There are conducted researches of calibration, metrological verification, and determination of the sensitivity of gammaray dosemeters, based on the joint application of installations equipped with ionizing radiation sources and of X-ray installations.The implementation of the Program of Integration of Ukraine into the European Union requires harmonization of Ukrainian and International standards, in the field of metrological assurance of means for measuring the characteristics of ionizing radiation including. Recently, several regulatory, methodological documents and issues have been published. They concern the dosimetric measurement of gamma-ray characteristics in the field of radiation safety, diagnostics, and therapy.
Анотація. Проаналізовано питання розвитку засобів еталонного забезпечення, необхідних для метрологічної перевірки та калібрування дозиметрів бета-та гамма-випромінювання. Останні вкрай необхідні для дозиметричних вимірювань характеристик випромінювання в області радіаційної безпеки, променевої діагностики та терапії. Окрім традиційних вимог та питань, пов'язаних із проектуванням, створенням та використанням зазначених еталонів, постає низка проблем, зумовлених радіаційною безпекою, як під час метрологічної перевірки та калібрування дозиметрів, так і під час створення та експлуатації самих еталонів. Розглянуто також питання передавання розміру одиниці вимірювання за допомогою еталонних іонізаційних камер процесі під час метрологічної перевірки/калібрування дозиметрів на установках типу УПД-Інтер. Показано, що проведення метрологічної перевірки/калібрування допускається для приладів, скомпенсованих енергетично. Ключові слова: дозиметр, еталонні установки, іонізуюче випромінювання, калібрування, метрологічне забезпечення, спектр.
The metrological risks of goods production are studied in the work. They are estimated conjugating with the existing technology as well as its metrological support. It is confirmed that in addition to the factors due to the processing of measurement results, the peculiarities of metrological support should be taken into account. One of the characteristic parameters of the metrological instruments is the variance of the measured value. Multiple measurements of the electrical resistance of the mentioned instruments - high-precision resistors designed for indirect measurement of current by measuring the voltage on them, using a DC bridge, were performed. The variance of obtained results is estimated, depending on the number of repeated measurements, the time interval between them, etc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.