Double PWM converter is the control core of doubly-fed wind power system. The traditional control mode is at most combined with PI controller. Under the unbalanced condition of the power grid, PI control method is very difficult to guarantee control requirements. This paper used the PR (proportion resonance) control method. while the controller can guarantee the system without the static sent output and rotor side active power and reactive power decoupling control , it also saves coupling term and a feed-forward compensation, reduces the number of coordinate transformation, still can effectively reduce the power grid frequency offset influence the inductance current of the inverter output , so as to improve the control precision of the algorithm and the grid power quality. Through the simulation test and the results analysis, it verifies the feasibility and accuracy of the theory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.